My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20905
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20905
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 11:07:28 AM
Creation date
1/14/2020 11:07:27 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-20905
Building Department - Name
BROEDERS,JEFFREY
Address
5704 9TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br /> 1. ALL FASTENERS SHALL RE DI ACCORDANCE WITH THESE <br /> FOR MAX. FRAME WIDTH, SEE PRESSURE TABLE <br /> DRAWINGS. SPECIFIED ANCHOR EMBED TO BASE MATERIAL SHALL ON THIS SHEET. <br /> BE BEYOND WALL FINISH OR STUCCO. FOR MAX, FRAME WIDTH, SEE PRESSURE TABLE -_ <br /> 2. OPENINGS,BUCKING&BUCKING FASTENERS MUST BE _ 6" 6" - <br /> PROPERLY DESIGNED&INSTALLED TO TRANSFER WIND LOADS TO ON THIS SHEET. k c <br /> THE.STRUCTURE 4 MAX. 12" MAX. O.C. 12" MAX. O.C. 4' MAX. s a <br /> 3. THESE NON-IMPACT RATED.PRODUCT INSTALLATIONS ARE IN Al 2" A2 <br /> ACCORDANCE WITH AND MEET THE REQUIREMENTS OF THE FLORIDA 3Aw <br /> BUILDING COIF(FBC). 3 <br /> 4. ALL ANCHORS SECURING PRODUCT FRAMES TO PRESSURE <br /> TREATED BUCKS OR WOOD FRAMING SHALL BE CAPABLE OF <br /> RESISTING CORROSION CAUSED BY THE PRESSURE TREATING 4" MAX. q <br /> CHEMICALS IN THE WOOD. R <br /> a. MATERIALS.INCLUDING BUT NOT LIMITED TO STEEL.SCREWS. w t_u <br /> 7HAT.COME DIM CONTACT WITH.OTHER DWML48 ATERLALS N= Bl FIN FASTENER WITHIN 2' vwi= 82 <br /> SWILL MEET THE REQUIREMENTS OF FLORIDA BUILDING CODE In rn v FRAME SCREWS WHERE SHOWN AT HEAD do SIDES. <br /> CHAPTER 20. ,= 4 OF CORNERS & 4 1/2' 4 s <br /> 6. TO THE BEST OF OUR KNOWLEDGE,THE PRODUCT SHOWN �= CLUSTER FlN FASTENERS MAX. O.C. WHEN JOB g= SEE 'FRAME ANCHOR REQUIREMENTS TABLE" ON THIS <br /> HEREIN IS CERTIFIED&OLWAY ASSURED BY A FLORIDA STATE w I AT MEETING RAIL ENDS REQUIRED DESIGN w H- SHEET FOR REQUIREMENTS. (NOTE THAT WHEN JOB v <br /> APPROVED CLRBFICATION/OA ENTITY&SHALL BE LABELED IN =Z SUCH THAT THERE AREA =z REQUIRED DESIGN PRESSURE IS OVER + -35 A <br /> PRESSURE IS OVER + -35 0 / <br /> ACCORDANCE wltH THE Fec AND THE FLORIDA DEPARTMENT of o / FRAME FILLER MUST BE USED AT EACH FRAME - <br /> BUSINESS&PROFESSIONAL REGULATION SPEGFlCAnors. J TOTAL OF 5 POSITIONED i pSF; 9' MAX. O.C. WHEN z w <br /> PRODUCT ASSEMBLY IS NOT PART OF THIS DRAWING AND SHALL m -AS.SHOWN. SEE "FRAME JOB REQUIRED DESIGN m SCREW, SEE SHEET 4 FOR PART'DETAIL) <br /> BE IN ACCORDANCE WITH THE MANUFACTURER'S DUALITY Ma. I Mi <br /> - -- ASSURAL�SPECLFlGLTI@S-ASSURANCE < ANCHOR-tEQU1IREMENLS—{ RESSURHS—r/-35-PSF-- ¢ ---- _ <br /> 7. CERTIFICATION OF THESE PRODUCT INSTALLATIONS SHALL BE w TABLE" ON THIS SHEET I w ' <br /> CONSIDERED VOID IF ANY OF THE FOLLOWING APPLY:1)PRODUCT OR LESS. SEE "FRAME <br /> FOR REQUIREMENTS. ANCHOR REQUIREMENTS � <br /> 5 INSTALLED WITHOUT A BURRING PERMIT FROM THE APPLCABIE N o Z <br /> LOCAL BUILDING DEPARTMENT. 2)PRODUCT IS INSTALLED 8Y o w TABLE'ON THIS SHEET O y�j I CD�-o <br /> ANYONE OTHER THAN A LICENSED CONTRACTOR EXPERIENCED WITH t<a j I FOR REQUIREMENTS. /� M'"(L 30 ¢ 00 <br /> INSTALLATIONS OF THIS TYPE OF PRODUCT. 3)IF CHANGES HAVE K <br /> OCCURRED TO THE PROOUCFS COMFICATION ENRTYS CERTIFICATE ' ow� I <br /> THAT CAUSE THESE INSTALLATIONS TO BE INCORRECT OR 4' MAX. 2 �'S N <br /> INCONSISTENT wm1 WHAT ws BEEN TESTED. EXTERIOR ELEVATION: o `o'�5 <br /> L THE LEAST DESIGN PRESSURE SPECIFIED EITHER IN THIS <br /> DRAWING OR IN THE PROOUCTS CERTIFICATION SHALL CONTROL FOR INSTALLATION CUPS WHERE EXTERIOR ELEVATION: a S N-A•�- <br /> THE INSTALLED PRODUCE XO WINDOW a o a m <br /> SHOWN AT SILL SEE "FRAME XO WINDOW CL- <br /> 9.THESE DRAWINGS CFITIIFY 1FIE PRODUCT INSTAIUTION ONLY. � <br /> WATER PROOFING OF THE INSTATED PRODUCT IS NOT PART OF SCALE: 3/4" = E'-O" ANCHOR REQUIREMENTS TABLE' I <br /> THIS INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE ON THIS SHEET FOR SCALE: 3/4' = 1'-O" z <br /> THAT OF THE MANUFACTURER&/OR INSTALLER (NAIL FIN MOUNT CONDITION) REQUIREMENTS. (FRAME SCREW AND CLIP MOUNT CONDITION) z <br /> FRAME ANCHOR REQUIREMENTS TABLE ri <br /> OPENING TYPE FRAME/CUP/NAIL FIN TO MINIMUM MINIMUM ilu <br /> (SUBSTRATE) OPENING FASTENER TYPE EMBED EDGE DIST. ALTERNATE ANCHOR/SUBSTRATE EVALUATION NOTE o <br /> ALLOWABLE DESIGN <br /> (1) FRAME SCREWS ALL ALTERNATE ANCHORS'IN THEIR SPECIFIED z <br /> PRESSURE SUBSTRATES HAVE BEEN ANALYZED IN ACCORDANCE MIN. 2X4 WOOD FRAME OR BUCK N0. 10 SAPS OR WOOD SCREW 1 1/4' 3/4' WITH THEIR APPLICABLE STANDARD(S)AND ARE FOUND m o0 <br /> (MIN. GR.3&G=0S5) (XO & OX UNITS) TO BE EQUIVALENT TO OR STRONGER THAN THE v1 Fm m <br /> MIN. 18 GA 33 KSI METAL STUD NO. 10 GR.5 SELF TAP DRILL SCREW FULL 1/2" MAX. MAX. ALLOWABLE ANCHOR(S) USED IN TESTING WITH THIS PRODUCT. <br /> MIN. 1/8'THK A36 STEEL NO. 10 GR.5 SELF TAP DRILL SCREW FULL 1/2- FRAME FRAME PRESSURE = F2- <br /> MIN. 1/8-THK 6063-T5 ALUM. NO. 10 GR.5 SELF TAP DRILL SCREW FULL 1/2- WIDTH HEIGHT (+/- PSF) INSTALLATIONEVAWAtON 6 BASED ON APPLICABLE ANCHOR STANDARDS s za.c!A <br /> MIN. C-90 CMU OR 2500 PSI CONCRETE W 1/4•CONCRETE SCREW 1 1/4- 2• (IN.) (IN.) ��B�R�MA6�7E 1�ION COFI✓�MED�E�1EALUAMN� W Wp. <br /> THAT IN FORCE AT THE TIME OF THE EVALUATION. IN THE MW OF CODE Of It - o i <br /> INSTALLATION__ CLIP.SCREWS, 52 1 4 62 50 W w � - <br /> --- VERSION LUNGES/UPDATES OR IN THE EVENT IHAT NEW OR ADDfTI0W1 <br /> MIN.2X4 WOOD FRAME OR BUCK 72 44 50 TESTING 6 COMPLETED ON THE REFERENCED PRODUCT PRIM TO STATING o W Fez <br /> NO. 10 SMS SCREW 1 1/4• 1/2- MOE CDMPLIANCE WITH THE STATE THE MANUFACTURER SHALL CONFIRM o :1, y <br /> (MIN. GR 3&G=0.55) 73 1 2 J2 2S WITH THE INS ALLATION EVALUATION 04ONMR OF RECORD THAT THE _N N cn 2w a <br /> INSTALLATIONS SPECIFIED HERE-IN ARE CURRENT WITH THE THEN CURRENT <br /> MIN. 1 B.GA 33 KSI METAL STUD NO. 10 GR.5 SELF TAP DRILL SCREW FULL 1/2' 78 62 25 TESTING.CODE,�nPnTc+eLL SrAloueUS. O <br /> MIN. 1/8'THK AS6 STEEL NO. 10 GR.5 SELF TAP/DRILL'SCREW-FULL 1/2' 96 62 30 �3L) <br /> MIN. 12 00 PSKI CONCRETE 6063-TS ALUM. N0.(2) 1/4•CONCRETE SCREW GR. 5 SELF TAP/DRILLSCREW 1 1/4" 122• PESSUE SHOWN IN THIS TABLE SR FOR RINSTALLATION CONDITIONS \\\��Q61 ��•,� y Z.�� <br /> ONLY. THE GOVERNING DESIGN �4 ..••°•••.•• m <br /> (3)NAILING FIN FASTENERS PRESSURE ON THE WINDOWS <br /> MIN.2X4 WOOD FRAME OR BUCK 1 3 8" 1 2" SHALT BE THE LESSER OF THAT LL i" a <br /> NO. B SMS SCREW Z Z cr) O O: <br /> / / x y�Z d �jt tW- Or.- <br /> 121-1 <br /> (MIN. GR.3&G=0.55) SHOWN IN THE INDIVIDUAL <br /> MIN.2X4 WOOD FRAME OR BUCK WINDOWS SATE APPROVAL OR MM Q < ",•O �o <br /> 11 GA ROOFING NAIL 1 3/8' 1/2' THAT SHOWN IN THIS TABLE O N�= " <br /> (MIN. GR.3&G=0.55) - !-' tom) O aW <br /> MIN. 1/8"THK A36 SEEL NO. 6 GR.5 SELF TAP/DRiU.SCREW FULL 1/2' '��'/�'••,�Z •�'co <br /> MIN. 1/8•THK 6063LE5 ALUM. N0. 8 GR.5 SELF TAP/DRILL SCREW FULL 1/2• �i�by•....•••'••�O\\\ <br /> (1)FRAME AND INSTALLATION CUP SCREWS SHALL BE A PAN'OR HEX HEAD SCREW. <br /> �M Q \ a <br /> (2)CONCRETE SCREWS SHALL BE L1C0 ULTRACONS (C.S.), ELCO CRETE-FLIX(S.S.), fIW FAliTED <br /> SE oPAwwrs ARE,wPLmMBLE ONLY ro THE PRODUCT o wi o. REY. -------- <br /> RAMSET/REO HEAD TAPCONS (C.S. OR S.S.) OR HILTI KWIK-CON It(C.S OR S.S.). CIFIED.THEY MAY Nor HE USED FOR THE ASSEMBLY $69 B <br /> (3)WHEN SCREWS ARE USED WLTH THE NAIL FIN,THEY MUST BE A WAFFLE HEAD SCREW OR HAVE Y 6E USED MR PwTIONAL 0/OR LOCA%L APPRMALY SHEET No. <br /> ANY PRODUCT NOT PRODUCED BY THE MANUFALRIRER <br /> A FLAT WASHER AT THE SCREW HEAD. 1 of rj <br /> ON TH SE ORAlMNGS <br />
The URL can be used to link to this page
Your browser does not support the video tag.