Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate ofAulhori:aiion No.9813 <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> NewSouth Window Solutions Sertes 9000 Model 9550 Slider XO <br /> Windows Horizontal Slider 4901 Oak Fair Blvd Impact Rated-HVHZ <br /> Tampa,FL 33610 w/Flange <br /> 813 626-6000 <br /> Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> NewSouth Window Solutions,based on Rule Chapter No.61G20-3,Method 1D of the State of Florida Product Approval, <br /> Dept.of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High <br /> . Velocity Hurricane Zone"(HVHZ). <br /> 2. Product arichars shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in the"HVHZ",this product complies with Section 1826 of the FBC and does not require an impact resistant covering. <br /> 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection,this product complies with Section 1609.1.2.2& <br /> R301.2.1.2.1.of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind <br /> Zone 4 as defined in ASTM.E 1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. <br /> 5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 6. Site conditions that deviate from the details of drawing FL-16842.E require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 7. This product meets water infiltration requirements for"HVHT'. <br /> 8. See drawing FL-16842.E for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> TEL 02031488 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. <br /> TEL 02031489 TAS 201,202,203-94 Testing Evaluation Lab. William S.Shelton,P.E. <br /> TEL 02031566 TAS 201.202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. <br /> 2. Miami Dade NOA Materials Testing <br /> 17-0712.04 Saflexo PVB Interlayer(Eastman Chemical Co.) <br /> 3. Drawing No, Prepared by Signed&Seated by <br /> No:FL-16842.6 RW Building Consultants,Inc.(CA#9813) ,'t►��<<eH 4i, Lyndon F.Schmidt,P.E. <br /> F,S MIS �,� <br /> 4. Calculations Prepared by �a� �;:•�G E S •.�. �� Sinned&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) �,Z Lyn n F.Schmidt,P.E. <br /> ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. t No 43409 ;• <br /> 5. Quality Assurance <br /> Certificate of Participation issued by.National Accreditation and STATE OF :�` Lyndon F.Schmidt,P.E. <br /> Management Institute,certifying that NewSouth Window Solutions is. p�...Al = FL PE No.43409 <br /> manufacturing products within a quality assurance program that complies 0,. �. •,t p R 1 d,:����� 10/12/2017 <br /> with ISO/IEC 17020 and Guide 63. Sheet 1 of 1 -i���'�'�ON <br /> eCa$����� <br />