Laserfiche WebLink
URNURNER1239 Jabara Ave. <br /> ER Port, FL 34288 <br /> ENGINEERING & Ph. 941-380-1574 <br /> TCONSULTING, INC. FBPE C.O.A. #29779 <br /> Evaluation Report 1151-R1 <br /> November 21,2016 <br /> Product Description: Series 8800 Vinyl Sliding Glass Door, Large Missile Impact Resistant.,5'nominal <br /> panel widths, 96"door heights,with design pressures of+/-80 psf,with heavy panel reinforcement <br /> required as shown in CWS-1151-RI <br /> Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h,Ave, Ocala, FL 34474 <br /> 'Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC <br /> Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 56' <br /> Edition(2014)Florida Building Code including the High Velocity Hurricane Zone. The product testing <br /> ,standards performed are outlined below. <br /> Technical Documentation: <br /> 1) This report, prepared by Lucas A.Turner, P.E., at 1239 Jabara Ave.,North Port,FL <br /> 2) Approval drawing CWS-1151-R1, signed and sealed by Lucas A. Turner, P.E. <br /> 3) Keystone Certifications CAR documents 138-571, 1601.0, and 1602.0 <br /> 4) Test Reports F1575.04/14-401-18/44,from Intertek/ATI,Tampa, FL(TAS testing signed/sealed <br /> by Justin P.McDonald),and CWS-010-02-03/04, by PRI Construction Materials Technologies, <br /> Tampa, FL(TAS testing signed/sealed by Zachary R. Priest),with testing performed: TAS <br /> 201/202/203-94,AAMA/WDMA/CSA 101/I.S.2/A440-11,ASTM E 1886-05,ASTM E 1996-09 <br /> 5) Supplemental Calcs.to support CWS-1151-R], signed and sealed by Lucas A. Turner, P.E. <br /> Installation: Units must be installed according to approval document CWS-1151-R1. <br /> Limitations of Use: This product: <br /> 0 May be used in sizes,design pressures, and with max. glass DLO sizes as shown in CWS-1151-RI <br /> • Is large missile(91b 2x4, 50 ft/s) impact'resistant and does not require the use of shutters <br /> 0 May be used in the High Velocity Hurricane Zone and ASTM Wind Zone 4 areas <br /> 0 Requires laminated glazing as shown in CWS=]151-RI,with Kuraray(prev. Dupont) .090" <br /> SentryGlas interlayer per Miami-Dade NOA 14-0916.11 <br /> • Requires Vision Extrusions PVC frames in accordance with NOA 15-0528.14 <br /> Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial <br /> interest in Custom Window Systems.or in any company manufacturing or distributing.products for which <br /> this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest <br /> in any other entity involved in the testing or approval process of this product. , <br /> `�y5ltfiifp�j <br /> lb <br /> 'r <br /> Lucas A. No �s2a� Z <br /> y P <br /> n • • ,� <br /> Turner . <br /> 2016-+1-21 a• 8TATra OF '' 11/21/2016 <br /> 10:37 19:00 . ,�, .�,c p . Lucas A. Turner P.E. <br /> t <br /> r <br /> �•° '' �Ne`. FL PE#58201 <br />