Laserfiche WebLink
D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one.place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R..O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property markers shall be uncovered.and marked at time of first inspection. <br /> 8-. All A.D.A. requirements shall be met: <br /> 9. No electric, plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location.where subject to mechanical damage unless <br /> protected by approved barriers. M303;4 of the F.B.0 <br /> 12. Waterheaters shall comply with section P607.3 of the.F.B.C. <br /> 13. Foundation supports for A/C-units-shall be raised at least 3" above finished grade. M I308.1 <br /> 14.Return air in all bedrooms. F.&C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of.the F.B.C. <br /> 16.All glazingrequirenieiits are to be in' accordance:with R308.4 of the F.B.C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 1 o. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and.electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />