Laserfiche WebLink
Q <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> I. F.F.E.. shall be a ininimum of 8" above the road elevation and an engineered site.plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or:more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway-thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be-met. <br /> 1. All.property:markers shall be uncovered-and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met: <br /> 9: No electric, plumbing;mechanical, or framing shall be:covered without an inspection and <br /> approval first. <br /> 10. All, Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308A <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be- installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4.0f the F.R.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18.' "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All.plumbing, mechanical, and electrical shall he separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />