My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21343
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21343
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2020 1:03:49 PM
Creation date
4/13/2020 1:03:30 PM
Metadata
Fields
Template:
Building Department
Company Name
BAHR'S PROPANE GASE & A/C
Building Department - Doc Type
Permit
Permit #
19-21343
Building Department - Name
BAHR'S PROPANE GAS & A/C
Address
3708 COPELAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Right-Suite@)Universal 2018 Load Summary Job: C0918485 <br /> wrightsoftu AHU1 Date: Sep 27,2018 <br /> By. AMA <br /> Project • • <br /> For: Bahr's Propane Gas&AC Inc <br /> 3708 Copeland Dr,Zephyrhills,FL 33542 <br /> Zone '4HU1- -- - - COOLING LOAD-- - -- - -- - - - — <br /> 1. DESIGN CONDITIONS atAug 1700 LDT Peak load atAug 1700 LDT <br /> Inside: 75 OF Outside: 92 OF TD: 17 OF <br /> RH: 55 % MoistDiff: 59.3 grAb Mult 1.0 Ins.wb 63 OF <br /> Sensible Latent <br /> 2. SOLAR RADIATION THROUGH GLASS 2550 - <br /> 3. TRANSMISSION GAINS Sensible 5677 Walls: 2705 - - <br /> Glass: 465 - - <br /> Doors: 774 - - <br /> Partitions: 0 - - <br /> Floors: 0 - - <br /> Ceilings: 1732 - - <br /> 4. INTERNALHEAT GAIN Sensible Latent 13161 1600 <br /> Occupants: 1900 1600 - - <br /> Lights: 3413 - - - <br /> Motors: 0 - -Appliances: 7848 0 - - <br /> 5. INFILTRATION: Outside air cf n: 9 165 363 <br /> 6. SUBTOTAL: Space load Sensible Latent 21553 1963 <br /> Envelope 21553 1963 - - <br /> Less external 0 - - - <br /> Redistribution 0 0 - - <br /> 7. SUPPLY DUCT 3843 - <br /> 8. SUBTOTAL: Space load+supply duct 25396 - <br /> Actual cfm: 1600 at supply TD: 20 - - <br /> 9. VENTILATION: Make-up air cfm: 111 2034 4469 <br /> 10. RETURNAIIR LOAD: Lighting+plenum(net) 0 - <br /> 11. RETURN DUCT 3602 - <br /> 12. TOTAL LOADS ON EQUIPMENT 31032 7800 <br /> ----- ----- - - ----- -- -- - - -- - HEATING LOAD _ - -- - - -- - - -- <br /> 13. DESIGN CONDITIONS Mult 1.0 <br /> Inside: 70 OF Outside: 43 OF TD: 27 OF <br /> 14. TRANSMISSION LOSSES 21683 <br /> Walls: 3581 - <br /> Glass: 918 - <br /> Doors: 683 - <br /> Partitions: 0 - <br /> Floors: 2680 - <br /> Ceilings: 13821 - <br /> 15. INFILTRATION: Outside air cfm: 22 659 <br /> 16. SUBTOTAL: Space load 22342 <br /> Envelope 22342 - <br /> Less external 0 - <br /> Less transfer 0 - <br /> Redistribution 0 - <br /> 17. SUPPLY DUCT: 2388 <br /> 18. VENTILATION: Make-up air cfm: 111 3304 <br /> 19. HUMIDIFICATION 1609 <br /> Piping 0 <br /> 20. RETURN DUCT 555 <br /> 21. TOTALHEATING LOAD ON EQUIPMENT 30198 <br /> -F- wrightsoi1-^ 2018-Oct-0511:03:53 <br /> a...•, �••— Right-Stite@Uriversal20l8l8.027RSW9290 <br /> Page 1 <br /> obs100918485-Balys•Batrs PropanekC0918485.ftp Calc=MN5 Buldirg Frortfaces:W <br />
The URL can be used to link to this page
Your browser does not support the video tag.