Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 ME-C <br /> 24. Iri accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot Water pipe insulation <br /> Insulation for hot water pipe with.a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping �14 inch (19.1 mm)and larger in nominal diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the.water heater to.a distribution manifold: <br /> .Piping located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower.door test shall be provided before C.O. <br /> 26.A cony of-the energy cacls-shall be with permit at all times <br /> 27 Cony of final.insulation report shall be provided with permit before rinaL <br /> 28. No fence,boot or screen enclosure .is issued with this hermit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />