Laserfiche WebLink
®TRII 11Y I ERD <br /> TABLE 2D: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE D-1: INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> System <br /> Insulation Layer(Note 14) Roof Cover MDP <br /> Roof Deck <br /> No. Type Attach Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld (psf)- <br /> (inch) (inch) (inch) (inch) <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-70 33 steel or min.2,500 psi more layers,any attach or TPO-c EXTRA HDP Fastener(concrete only)and Mule- 6 5.5 138.5 1.5 -52.5 <br /> structural concrete combination Hide 2.4"Seam Plate <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-71 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 6 5.5 91 1.5 -52.5 <br /> structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate <br /> Min.22 ga.,type B,Grade <br /> 33 steel,6 ft span,5/8" Min.1-inch,one or <br /> diameter puddle welds 6" Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide <br /> SC-72 o.c.,side laps secured 24" more layers,any attach or TPO-c EXTRA 2.4"Seam Plate 6 5.5 90.5 1.5 52.5 <br /> o.c.w/%"-14x1"long self- combination <br /> tapping hex-head screw <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-73 33 steel or min.2,500 psi more layers,any HDP Fastener(concrete only)and Mule- 12 5.5 42.5 1.5 -52.5 <br /> structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate <br /> Min.22 ga.,type B,Grade Min.1-inch,one or <br /> 33 steel,6 ft span,5/8" more layers,any <br /> SC-74 diameter puddle welds 6" combination(optional Prelim. Mule-Hide TPO-c Mule-Hide EHD Fastener and Mule-Hide 6 5.5 138.5 1.5 -60.0 <br /> o.c.,side laps secured 24" for recover)followed attach or TPO-c EXTRA 2.4"Seam Plate <br /> o.c.w/%"-14x1"long self- by 3/8-inch Insulfoam <br /> tapping hex-head screw R-Tech EPS or Fan-Fold <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Mule-Hide EHD Plus Fasteners and <br /> SC-75 33 steel or min.2,500 psi more layers,an Prelim. Mule-Hide TPO-c Mule-Hide 2.4" PLUS Seam Plate(steel <br /> p y attach orTPO-c EXTRA only)or HDP Fastener and Mule-Hide 6 5.5 138.5 1.5 60.0 <br /> structural concrete combination <br /> 2.4"Seam Plates <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> attach or TPO-c E <br /> SC-76 80 steel or min.2,500 psi more layers,any Prelim. Mule-Hide EXTRA RA HDP Fastener(concrete only)and Mule- 6 5.5 138.5 1.5 -60.0 <br /> structural concrete combination Hide 2.4"Seam Plate <br /> Min.1.5-inch,one or <br /> Min.22 ga.,type B.Grade more layers,any Loose Mule-Hide TPO-c Mule-Hide EHD Fastener(steel only)or <br /> SC-77 33 steel or min.2,500 psi combination followed HDP Fastener(concrete only)and Mule- 6 5.5 91 1.5 -60.0 <br /> structural concrete by 3/8-inch Insulfoam laid or TPO-c EXTRA Hide 2.4"Seam Plate <br /> R-Tech EPS <br /> Min.22 ga.,type B,Grade Min.1.5-inch,one or Mule-Hide EHD Fastener(steel only)or <br /> SC-78 33 steel or min.2,500 psi more layers,any Prelim. or TPC-c E TRATPO HDP Fastener(concrete only)and Mule- 12 5.5 54.5 1.5 -60.0 <br /> structural concrete combination attach or TPO-c EXTRA Hide 2.4"Seam Plate <br /> Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS <br /> Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 14 of 27 <br />