Laserfiche WebLink
l-RINITY ERD <br /> TABLE 2E: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED ROOF COVER(RUSS Strips) <br /> System Deck Insulation Roof Cover MOP <br /> No. Type Attach Membrane Fasteners Attachment (psf) <br /> Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation <br /> Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 138-inch o.c. The plates are centered over each strip and fastened 6- <br /> SC-84 layers,any TPO-c or TPO-c -30.0 <br /> 2,500 psi structural combination attached EXTRA only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape <br /> concrete Plates Primer at the strip location,then rolling into place with a hand roller. <br /> Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation <br /> Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 114-inch o.c. The plates are centered over each strip and fastened 6- <br /> SC-85 layers,any TPO-c or TPO-c -45.0 <br /> 2,500 psi structural combination attached EXTRA only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape <br /> concrete Plates Primer at the strip location,then rolling into place with a hand roller. <br /> Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation <br /> Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 90-inch o.c. The plates are centered over each strip and fastened 6 <br /> SC-86 layers,any TPO-c or TPO-c - -52.5 <br /> 2,500 psi structural attached only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with TPO Tape <br /> concrete combination EXTRA Plates Primer at the strip location,then rolling into place with a hand roller. <br /> Min.22 ga.,type B, Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation <br /> One or more Mule-Hide <br /> Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 120-inch o.c. The plates are centered over each strip and fastened 6- <br /> SC-87 layers,any TPO-c or TPO-c -60.0 <br /> 2,500 psi structural attached only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with HP-250 <br /> concrete combination EXTRA Plates Primer at the strip location,then rolling into place with a hand roller. <br /> Min.22 ga.,type B, One or more Mule-Hide Mule-Hide EHD Fastener(steel TPO 10-inch Pressure-Sensitive RUSS strips are applied over the insulation <br /> Grade 80 steel or min. Prelim. only)or HDP Fastener(concrete spaced 60-inch o.c. The plates are centered over each strip and fastened 12- <br /> SC-88 layers,any TPO-c or TPO-c -60.0 <br /> 2,500 psi structural combination attached EXTRA only)and Mule-Hide 2.4"Seam inch o.c. Roof cover adhered to each strip by first priming with HP-250 <br /> concrete Plates Primer at the strip location,then rolling into place with a hand roller. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL12772-RS <br /> Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 16 of 27 <br />