Laserfiche WebLink
EXTERIOR RESEARCH&DESIGN, LLC. <br /> F)o Certificate of Authorization#9503 <br /> T <br /> p tA'I�/I ER® 353 Christian Street <br /> 1� N�I 1 ' Oxford,CT 06478 <br /> (203)262-9245 <br /> EVALUATION REPORT <br /> Mule-Hide Products Co., Inc. Evaluation Report M15060.06.09-R5 <br /> 1195 Prince Hall Drive,Suite A FL12772-R5 <br /> Beloit,WI 53511-5481 Date of Issuance:06/24/2009 <br /> (608)365-3111 Revision 5:09/11/2017 <br /> SCOPE: <br /> This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of <br /> construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, <br /> P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for <br /> compliance with the 6th Edition(2017)Florida Building Code sections noted herein. <br /> DESCRIPTION: Mule-Hide TPO-c Single Ply Roof Systems <br /> LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted <br /> herein. <br /> CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced <br /> Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of <br /> this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product <br /> changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this <br /> Evaluation Report relative to updated Code requirements with each Code Cycle. <br /> ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in <br /> advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. <br /> INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or <br /> its distributors and shall be available for inspection at the job site at the request of the Building Official. <br /> This Evaluation Report consists of pages 1 through 4, plus a 27-page Appendix. <br /> Prepared by: <br /> apltgtgtifrnr,q� <br /> :w: <br /> i <br /> Robert J.M.Nieminen,P.E. �o�•.�,:•: t f r ; ; <br /> �r,FS The facsimile seal appearing was authorized by Robert Nieminen, <br /> Florida Registration No.59156,Florida DCA ANE1983 1!,��� at ti�a�w P.E.on 09/11/2017.This does not serve as an electronically signed <br /> document. <br /> CERTIFICATION OF INDEPENDENCE: <br /> 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest <br /> in any company manufacturing or distributing products it evaluates. <br /> 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or <br /> distributing products it evaluates. <br /> 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for <br /> which the evaluation reports are being issued. <br /> 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the <br /> product. <br /> S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any <br /> project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained <br /> specifically for that purpose. <br /> 1 <br />