My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21471
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21471
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2020 9:09:17 AM
Creation date
4/15/2020 6:36:42 AM
Metadata
Fields
Template:
Building Department
Company Name
ALPHA VILLAGE
Building Department - Doc Type
Permit
Permit #
19-21471
Building Department - Name
MORROW-DULIER,MARSHA & DIXON,JEAN
Address
38604 TRELLIS AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TRJNJ FAD' <br /> ¢_4 Wind Classification: <br /> 5.4.1 All Owens Corning asphalt shingles.noted herein are Classified.in accordance with FBC Tables 1507.2:7.1'" <br /> and R905.2.6:1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingle's are acceptable . <br /> 'for use in all.wind zones up to Va,d = 150 mph (V„tt,= 194'mph), Refer to Section 6 for installation. <br /> requirements to meet this.wind rating. <br /> 5.4.2 . .All Owens Corning flip & ridge shingles,-Starter Strip Shingle: and Starter"Strip Plus noted herein.are <br /> Classified-in accordance with.FBC Tables.1507.2.7.1-and R905.2.6.1 to ASTM D3161,Class F,indicating the', <br /> shingles are acceptable"for use in all wind zones up to Va,d=150 mph(Volt=194 mph). Refer to Section 6•for <br /> installation requirements to meet this wind rating. <br /> 5.4.3 Classification by ASTM 071,58.applies to,exposure"category'B-or C,.as'defined in FBC 1609:4.3,and a mean' <br /> roof,height of 60 feet or less:,.Calculations;by a qualified design professional are required for:canditions <br /> outside these iimitati.ons.'Contact the shingle manufacturer-for data specific to each shingle: . <br /> 5.4.4" Refer to Owens Corning published information on"wind resistance and installation limitations. <br /> 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G203. <br /> C. INSTALLATIC)N: <br /> 6;1• Underlavment:' <br /> 6.1-1 Underlayment shall be acceptable"to Owens• Coming, and shall -hold .current Florida Statewide Product. <br /> Approval,or be Locally Approved per-Rule 61G20-3,pet FBC 1507.23,1507.2.4 or R905.23: <br /> 6.2 Asphalt Shingles <br /> 6.2.1 Installation of asphaltshingles"shall comply with the Owens-Corning current published instructions, using <br /> minimum four (4) nails per shingle-in accordance with FBC 1507.2.7 or "11905.2.6. 'With the following . <br /> exceptions: <br /> ➢ Berkshire shingles require minimum five(5)-nails per shingle. <br /> ➢ WeatherGuard*W shingles require minimum,six(6)nails.per shingle. . . <br /> D Devonshire'n"shingles require minimum six(6)nails.per shingle. . <br /> A StarterStrip-Shingle"and Starter Strip Pius require minimum five(5)nails"per strip. <br /> Refer to Owens Corning published information on wind resistance and installation limitations.. <br /> 6.2.2- Fasteners shall be in accordance with the.manufacturer's published requirements, but not Less than FBC. <br /> 1507.2.E or R905.2.5. Staples are not permitted. <br /> 6.2.4. Where the roof slope exceeds 21 units vertical in:12 units horizontal, special-methods of_fastening.are " <br /> required. See figures below for•details. <br /> 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: <br /> Feitunderlayment Deck Fehunderhymem � Sditdhered <br /> i, - WeaduffLocktl' . <br /> ` _ Seta-adhered uridedaymort <br /> WeathecLockr' <br /> underlayment C <br /> r Drip ed& <br /> Orip_ Drip edge Drip=- r <br /> edge �9a <br /> 'Nails iotated' Naas tacita: <br /> 2'=3"from save -2'3'fmmsm <br /> Install first Self-sM* adhesive SdteeaGnsadhaaiva <br /> SiatierStitrpp - lnsta�raststarterStripP6n - • - <br /> shingie t vat rnmo <br /> -Positioned a,.fig 'h S" red -' posi8oined atong eaw <br /> S"removed -" \\ <br /> Starter Strip shingle overhangs eaves and rakes.%"-.4" SYerterSWp Phn oved"O'seaves and rakes 1/4-V47 <br /> Exterior ReseamWand Design,LLC" Evaluation Report'037940.07-12-R8' <br /> Cew leate ofAothorizotron#9503 - f'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 <br /> Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017. <br /> Page j <br /> of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.