Florida Building Code Online Page 2 of 3 <br /> Summary of Products <br /> FL# -� Model,Number or Name Description <br /> 4904.1 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and O/S Single Door <br /> Units <br /> limits-of-Use- Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.01.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+76.0/-76.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0128.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514010A.odf <br /> 3'-0"x 6'-8"max nominal size.When large missile impact Created by Independent Third Party:Yes <br /> resistance is required,hurricane protective system is NOT <br /> required.See DWG-MA-FLO128-05 for details. <br /> 4904.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S and O/S Single Door <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.02.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+70.0/-70.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514009A.odf <br /> 3'-0"x 8'-0"max nominal size. When large missile impact Created by Independent Third Party:Yes <br /> resistance is required, hurricane protective system is NOT <br /> required.See DWG-MA-FLO129-05 for details. <br /> 4904.3 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and O/S Door w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.0l.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure: +55.0/-55.0 Installation Instructions <br /> Other: Evaluated for use in locations adhering to the FL4904 R8 II FL0128.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514008A.odf <br /> 12'-0"x 6'-8"max nominal size.When large missile impact Created by Independent Third Party: Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels, but is required on glazed panels. <br /> See DWG-MA-FL0128-OS. <br /> 4904.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Door w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.02.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure:+45.0/-50.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> Zone,and where pressure requirements as determined by Created by Independent Third Party: <br /> ASCE 7,Minimum Design Loads for Buildings and Other Evaluation Reports <br /> Structures,does not exceed the design pressures listed. FL4904 R8 AE 514007A.13df <br /> 12'-0"x 8'-0"max nominal size. When large missile impact Created by Independent Third Party: Yes <br /> resistance is required,hurricane protective system is NOT <br /> required on opaque panels,but is required on glazed panels. <br /> See DWG-MA-FL0129-05. <br /> 4904.5 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S w/or w/o Sidelites <br /> Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.02.odf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:Yes 12/31/2020 <br /> Design Pressure: +50.0/-45.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the FL4904 R8 II FL0129.odf <br /> Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute <br /> https:Hfloridabuilding.org/pr/nr_app_dtl.aspx?param=wGEVXQwtDgteluIWHNbblS ci0%2b... 1/9/2018 <br />