Laserfiche WebLink
FORM R405-2017 <br /> FLO141DA ENERGY EFFICIENCY CODE-FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali 1828 Elev D• Builder Name: DRH Express'Homes <br /> Street: 7iDI� �'I V_ (?�1 VC[ Permit O#fice: <br /> City,State,Zip: Zephyrhi s,,- 2 `` Permit Number: <br /> Owner: 3354' LV Jurisdiction: <br /> Design Location: FL,Tampa- I �j)� County: Pasco(Florida Climate Zone 2}• <br /> 1. New construction or existing New(From Plans) ! 9:-Wall Types(1710.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.'Concrete Block-Int lnsul,Exterior R=4.1 1404:00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A = R= ft2 <br /> 4. Number of Bedrooms 4'. d.N/A R= ft2 <br /> 5. is this a worst case? No 10.Ceiling Types (1828:0 sgft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned.floor.area above grade(ft2) 1828 b:N/A R= f#? <br /> Conditioned floor area below grade(ft2) 0 ; c.N/A R= ft2 <br /> 11.Ducts R ft2 ' <br /> N 7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> p a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,0=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A W <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump • 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: .0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sgft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b.•Conservation features <br /> b.N/A R= ft2 None <br /> c.NIA R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: •60.57 <br /> Giass/Float Area: 0.091 p <br /> }) Total Baseline Loads: �61.29 _ <br /> SS <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> 40 <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance r� ' -: ^,,�t ylk <br /> with the Florida Energy Code. nrrf: trr, r;,.= -`''w," 4L C3 <br /> PREPARED BY: sPcompleted ;f.. <br /> ,,,�.k Before construction is � <br /> 1 Cr <br /> DATE: 3-N-19 this building will be inspected for <br /> compliance With.Section 553.908 . <br /> Florida.� 1 hereby certify that this building, as designed,is in compliance Flor Statutes. - •rj.� ,fig ..;. <br /> with the Florida Energy Code. Q� <br /> OWNER/AGENT: • Q-' '' BUILDING OFFICIAL:' <br /> 'DATL: , DATE:. <br /> Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as. <br /> certified factory-sealed 16accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires art <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).. . <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct teakage�to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for Whole house. <br /> 3/14/2019 11:16 AM EnergyGaugeO USA Section.R405.4.1 Compliant Software Page i of 4 <br />