Laserfiche WebLink
ProjectSummary Job:: <br /> - - wrightsoft® Entire House by:. <br /> Progressive Air Systems; Inc Plan: 1828Ca1i <br /> 5907 Dasher Of,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Prooect Information <br /> For: DR-Horton <br /> Lot 13 Blk 7 Silverado, Zephyrhills, FL <br /> Notes: <br /> Didsign Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter. Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF. <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb. <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure . 17435 Btuh Structure 15417 Btuh <br /> Ducts 4558 Btuh Ducts 5554 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm). 0 Btuh, <br /> none <br /> Humidification 0 Btuh - Blower. ) 0 Bfuh <br /> Piping 0 Btuh <br /> Equipment load 21992 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load . 20971 Btdh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2347 Btuh <br /> Ducts 1300 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1820 1820 Equipment latent load 3647. Btuh <br /> Volume (ft3) 15855 15855 <br /> Air changes/hour 0.26 0.14 Equipment total load 24618 Btuh <br /> Equiv.AVF(cfm) 69 37 Req.total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO30 Cond CH14NBO30 <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling .22500 Btuh' <br /> Heating output. 29600 Btuh @ 47OF Latent cooling 7500 Btuh <br /> Temperature rise . 271 OF Total cooling . 30000 -Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.045-.cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.45 in H20, Static pressure 0.45 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point=33 OF <br /> Backup: <br /> Input=7 kW, Output:=22477 Btuh, 100-AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri htSOft" 2019-Mar-1411:16:56 <br /> g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 -House Front faces: W <br />