Laserfiche WebLink
NOTES FOR STANDARD ELECTRICAL DIAGRAM <br /> rn <br /> SIGNS-SEE GUIDE SECTION 7 <br /> NOTES FOR ALL DRAWINGS: SIGN FOR DC DISCONNECT <br /> PV_MODULE_RATINGS1@ STC(Guide-Section,5) <br /> MODULE MAKE Mission Solar OCPD=OVERCURRENT PROTECTION DEVICE PHOTOVOLTAIC POWER SOURCE <br /> NATIONAL ELECTRICAL CODE'REFERENCES �RATED MPP CURRENT 1 18.8 A <br /> MODULE MODEL MSE 310SQ8T SHOWN AS(NEC)CXX.XX) <br /> RATED MPP VOLTAGE 299 v <br /> MAX POWER-POINT CURRENT(1..) 9.4 A MAX SYSTEM VOLTAGE 362 v <br /> MAX POWER-POINT VOLTAGE(V,p) 33.2 v INVERTER RATINGS.,(Qui-de.Sec-tion 41) <br /> MAX.CIRCUIT CURRENT 19.6 A 0 <br /> OPEN-CIRCUIT VOLTAGE(Vo,) 40.2 v INVERTER MAKE I SMA <br /> WARNING:ELECTRICAL SHOCK <br /> SHORT-CIRCUIT CURRENT(1,,) 9.8 A INVERTER MODE is HAZARD—LINE AND LOAD MAY BE <br /> MAX SERIES FUSE(OCPD) 20 A <br /> MAX DC VOLT RATING 600 v ENERGIZED IN OPEN POSITION <br /> MAXIMUM POWER(P,,,,) 310 W MAX POWER @ 40°C 7680 IN S1,019 FOR INVERTER OCPD AND <br /> AC DISQONNECT.(IIEU�SED) <br /> MAX VOLTAGE(TYP 600voc) 600 V NOMINAL AC VOLTAGE 240 _V SOLAR PV-SYSTEM ;< <br /> VOC TEMP COEFF(rnV/1C[]or%/OC Nf) -0.280 MAX AC CURRENT 32 A AC POINT OF CONNECTION 5; <br /> IF COEFF SUPPLIED,CIRCLE UNITS MAX OCPD RATING 40 A AC OUTPUT CURRENT 32 A Z< <br /> NOMINAL AC VOLTAGE 240 v <br /> THIS PANEL FED BY MULTIPLE 0 <br /> SOURCES(UTILITY AND SOLAR) tJ <br /> NQjES_FQR ARRAY:CIRCUIT WIRING(Guide Section_6_and 8_and-Appendix D): NOTES.FOR INVERTER CIRCUITS(Guide Section 8and 9): 0 <br /> 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br /> EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO 1)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS SWITCH MEET THE <br /> INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP C REQUIREMENT? YES 0 NO[I NIA IX <br /> (D <br /> 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST 2)IF GENERATION METER REQUIRED,DOES THIS METER SOCKET MEET THE ca <br /> MONTH 2%DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO REQUIREMENT?YES EI NO 0 NIAX < <br /> INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMPERATURE C U <br /> 3)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS BASED ON MAX 1-11 <br /> 2.)2005 ASHRAE FUNDEMENTALS 2%DESIGN TEMPERATURES DO NOT EXCEED CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT Uj <br /> 47°C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1-C).FOR LESS THAN 9 <br /> CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT 4)SIZE INVERTER OUTPUT CIRCUIT(AC)CONDUCTORS ACCORDING TO INVERTER <br /> LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF OCPD AMPERE RATING.(See Guide Section 9) < <br /> 47°C OR LESS(ALL OF UNITED STATES), 1 C� <br /> 5)TOTAL OF INVERTER OCPD(s),ONE FOR EACH INVERTER.DOES TOTAL < <br /> a)12 AWG,90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 690.64(B)(2)(a)? <br /> WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER YES R NO <br /> FUSE. _j <br /> b)10 AWG,90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br /> WITH Ise OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER Contractor Naine. Notes for One-Line Standard Electrical <br /> FUSE. Address and Phone: <br /> Tampa Bay S far Diagram for Single-Phase PV Systems <br /> 48n7 N HALEAVE Site Name: Holzschuher Residence <br /> rnnaFl_ 4 Site Address: 6431 Huntington Dr <br /> —8968Z <br /> System AC Size: 240V/32A <br /> SIZE FSCM NO DWG NO REV <br /> 0-11yR Espinosa <br /> E1.2 <br /> Checked By: S Rutherford ISCALE NTS Date: --F,--.T <br />