Laserfiche WebLink
D , <br /> Q <br /> d <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall-be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to.comply with R401:3'of the F.B.C: <br /> 3. Compaction test required if 247or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways require.a R,O:W. use permit: All 4 sides of driveway thru the sidewalk_shall have <br /> expansion material. . <br /> 6. .All setbacks shall be met. <br /> 7. All,property markers shall be uncovered and marked at time of first inspection. <br /> .8: All A.D.A.requirements shall be.met: <br /> 9: No electric,.plumbing;mechanical, or,framing shall be covered without an inspection.and <br /> approval first. <br /> 10: All Garages shall comply with section:R302.6 of the F.B-C. (Fire Separation). <br /> 1 L Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall'comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least'3" above finished grade. M1308.:1: <br /> 14: Return air in all bedrooms. F.B:C. M162.0.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of.the F.B.C. <br /> 16.All glazing requirements are to be-in accordance-with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance-with R31 I of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. <br /> 19.-Combination-type AFCI:breakers are required at all locations requiring an AM.type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All,plumbing,mechanical, and electrical shall be separate from unit to unit: This includes-all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />