Laserfiche WebLink
4 <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25:.R403.5.3Hot water pipe insulation <br /> Insulation for hot.water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3/: inch (1.9.1 mm) and larger in nominal diameter. <br /> Piping.serving more-than one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the Water heater to a distribution manifold. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower.door test shall be provided before C.O. <br /> 26.A copy ofthe enerzy.cacls shall be with permit at all times <br /> 27. Copy of final insulation report shall be provided ivith permit before rnal <br /> 28 No fence, pool or screen enclosure Is issued with this-permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6a'Edition <br /> R.O.W:-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />