Laserfiche WebLink
23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25..R403.5.3Hot water pipe insulation <br /> insulation for hot water pipe with a minimum thermal resistance (R-value)of R-3 shalt be applied to the <br /> following: <br /> Piping 31<inch (19.1 mm)and larger in nominal diameter. <br /> Piping,serving more than:one dwelling unit: <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O: <br /> 26. A copy ofthe enerzy-cacls shall be with permit at all times. <br /> 27. Copy of final insutatiort report shall be prtiuided with permit before fnaL <br /> 28.1 No fence,pool or screen enclosure .is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />