Laserfiche WebLink
Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017.Florida.Building Code;-Energy-C•onservation, 6th Edition <br /> Jurisdiction:" Permit#: <br /> Job.In o- rmation <br /> Builder: MASTER CONST Community: Lot: <br /> Address: 38401 12th Avenue <br /> City: ZEPHYRHILLS,FL State: FL Zip: 33542 <br /> AIr..Leakage Test Reslults. Passin-omsuits must meeteitherLthe;Peifomlance,Prescriptive, orEMAjethod <br /> g PRESCRIPTIVE METHOD-Ttie building or dweiling unit shail-be tested_and verified as having an air leakage rate.of`not,exceedin 7;"air='=r <br /> 9 <br /> changes per;hourat a pressure of O.2"inch w.g:(50,Pascals),in Climate Zohes 1 and 2s <br /> ' ? ` PERFORMANCE or ERl METHOD-The buildin or"dwellin uiiit'shall be tested and"verified•as haviri an.air leaks e!rate.of not:ezceedin <br /> the selected ACH(50)value;.as-shown.on Form.R406=2017(Performance)or 14406-2017.(ERI);,section`labeled-as'infiltration;sbb-section.ACH_50... <br /> ACH(50)specifreol on Form R405-2017-Energy Calc(Performance)orR406-2017(EOIJ <br /> 1203 X 60.. 11,560.54 6.249 Method for calculatin4 building-volume: <br /> CFM(50). Building Volume .;,. ACH(50) Retrieved from architectural plans <br /> x ® .PASS"' -. <br /> Q Code.software calculated <br /> When ACH(50)is less than 3, Mechanical Ventilation installation 0Field`measured and calculated <br /> must be verified by building department. <br /> R402.4.1.2 Testing.Testing shall be-conducted in accordance with ANSURESNETAW380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). <br /> Testing shall be conducted by either,individuals as defined in Section 553.993(5)or(7);.Florida Statues.or individuals licensed as set forth in Section. <br /> 489.105(3)(0,(g),or(ii)-or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and <br /> provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. <br /> During testing: <br /> 1.Exterior windows and doors,.frreplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration, <br /> control measures. <br /> 2.Dampers including'exhaust,intake,:makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control <br /> measures. <br /> 3:Interior doors,if installed at the-Aime of the test,shall be open. <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.Heating and cooling systems;if installed at the time of the`test,`shall be turned off. <br /> 6.Supply and return-registers,,if installed of the time of the test;shall be fully open. - <br /> ,epting Company <br /> Company Name: Iafiraite' Energy Solutions Phone:' 1-844'-BSTARFL . <br /> I hereby verify that the above;Air Leakage results are.in accordance with the 2017 6th Edition Florida,Building Code <br /> Energy Conservation requirements according to the compliance method selected;above. <br /> Signature of Tester:_ Date of Test: 2/26/20 <br /> Printed Name of Tester: David Murphy <br /> License/Certification#: 64FC86 Issuing Authority: RBSNET <br /> EnergyGa6getUSA'6.0:02-FlaRes2017 FBC 6th"Edition(2017)Compliant Software Page 1 of 1 <br />