Building Department - Name
KINCAID,JACK & SHARON
Address
38102 12TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-Q TR TY I ERD <br /> SA Wind Classification: <br /> 5.4.1 A{1 Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2-7.1' <br /> and 11905.2.6:1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are,acceptabie . <br /> for use"in -all wind zones up to 'V;I,d'= 150 mph (Vult = 194 mph), Refer to Section-6 foe installation . <br /> requirements to meet this"wind rating. <br /> 5.4.2 . All Owens Corning hip & ridge shingles, Starter Strip Shingle. and Starter'Strip Plus noted herein .are <br /> Classified in,accordance with.FBC Tables 1507.2.7.1 and R965.2.6.1 to ASTM D3161,Class'F,indicating the . <br /> 'shingles are acceptable for use in all wind zones up to Vasd=150 mph(Vult=194 mph). Refer to Section 6 for <br /> installation requirements to rneet:this wind'rating. <br /> 5.4.3'. Classification by ASTM D71S8 applies to exposure category B or C,"as defined'in FBC 1609A.3,and.a mean. <br /> roof height of 60 feet or less:. Calculations by.a qualified design professional,are:required forconditions <br /> outside these limitations: Contact the shingle manufacturer fordata specific to each shingle.; <br /> 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. <br /> 5.5 All products in the roof assembly shall have quality assurance audit"in accordance with F.A.C.Rule 61620- <br /> 6. (NSTALtAT10N: <br /> '15.1 Underlavment:. ." <br /> i.1.1' . Underla merit shall be acceptable to Owens Cornin , and.shall 'hold current Florida Statewide Y P g e i'roduct. <br /> Approval,or be Locally Approved per Rule 61G20-31 per FBC"1507.2.3,1507.2.4 or R905.2.3. <br /> 6_2 Asphalt Shingles: <br /> 6.2.1• Installation of asphalt shingles shall comply with the Owens-Corning current,published.instructions,.using. <br /> minimum four (4) nails per shingle" in accordance with FBC 1507.2.7 or R905.2.6, with the following " <br /> exceptions: . " . . <br /> ➢ Berkshire`shingles require minimum five(5).nails per sh-iingle. <br /> ➢ WeatherGuarde HP shingles require minimum six(6)nalls.per shingle. <br /> ➢ DevonshireTM'shingles require minimum six(6)nails per shingle. <br /> Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. <br /> Refer to Owens Corning published"information an wind-resistance and installation limitations. <br /> 6.2.2 fasteners shall be in accordance with the manufacturer's published requirements, but not Tess than FBC <br /> 1507.7.6 or R905.2.5. Staples are not permitted. <br /> 6.2.4 Where the.roof slope exceeds 21 units vertical in 12 units horizontal, special methods of.fastening are <br /> required. see figures below for details. <br /> 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: <br /> Felt underlayment Deck Felt unduf3yment Deck Self�dherad, <br /> Wothe�L i,. <br /> Sell-adhered ondadaymonf <br /> WeatherLocke -� <br /> `tc underlayment <br /> Drip Drip edge DOp <br /> edge - <br /> Nails located <br /> Nails locates! 2-�`{mm eava <br /> 2"=3`from gave <br /> Install first Self-sealing adhesive. Sell4ealing adhesive <br /> Instagraststm-e,stri Pius <br /> Starter Strip .positioned along eava. p - - positioned <br /> along eava <br /> Shingle with - \'� :. �With tr removed .Y -- - <br /> 6"removod <br /> Starter Strip shingle overhangs eaveis'and rakes 4i=ii' Smrtu 5ttip Pin ovcrhunps eaves andrakes l/4=7/4 <br /> 'Exterior,Research and Design,I.I.C. Evaluation Report 037940.02.12-R8' <br /> Certifhate ofAutharizatlan tt9$03 6 EDITION(2017)FSC NON-HVHZ EVALUATION, FL10674-1113 <br /> Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017. . <br /> Page 3 of 8 <br />