ec on, <br /> '444 iinicaT 1166g In, Plans Verified _ . Field'VeriFed <br /> ilnspectioti, Value. Value` <br /> Complies? C®r»ments/Assurnpticins <br /> 6.4.1.4, 1 HVAC equipment efficiency Efficiency: Efficiency: ;[]Complies ,See the Mechanical Systems list <br /> 6.4.1:5 verified. Non HVAC ❑Does Not ;for values. <br /> [MEl]2 !equipment labeled as meeting <br /> ,9Q.1. I ;❑Not Observable , <br /> ❑Not Applicable <br /> 6.4:3.4A !Stair and elevator shaft vents ;Y ` . = , f 9"" ❑Complies <br /> [MEV .. .. :have motorized dampers that :❑Does Not <br /> ..lautomaticallyclose. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> Q..4:3.4.5 .;Enclosed parking garage ❑Complies <br /> [ME39]3-. ;ventilation has automatic g : . , ': ❑Does Not <br /> tcontaminant detection and <br /> capacity to stage or modulate ❑Not Observable <br /> Mans to 50%or less of design ❑Not Applicable <br /> Icapacity. " <br /> s i <br /> 6.4.3":4.4.,;Ventilation fans>0.75 hp have �: ','o i Yji'' � ❑Complies <br /> [ME5]3.. lautornatic controls to shut off fan �, l cf. N, ❑Does Not <br /> ,when not required. <br /> ❑Not Observable ; <br /> f ' ❑Not Applicable <br /> 6.4.3.8 ;,Demand control ventilation ❑Complies <br /> [ME6]1 !provided for spaces>500 ft2 and ❑Does Not <br /> ii>25 people/1000 ft2 occupant <br /> :density and served b systems ❑Not Observable <br /> Y Y Y ' <br /> with air side economizer,auto ❑Not Applicable <br /> modulating outside air damper <br /> !control, or design airflow>3,000 7 <br /> s cfm. _ <br /> N s6j,. <br /> 6.5.3.2',1 i DX cooling systems >= 75 kBtu/h '"" ��/ '6 "f ❑Complies ;See the Mechanical Systems list <br /> [ME40]2 -i(>= 65 kBtu/h effective 1/2016) ' ' ❑Does Not ;for values. <br /> land chilled-water and <br /> „ <br /> !evaporative cooling fan motor hp ❑Not Observable <br /> >= 1/4 designed to vary indoor ❑Not Applicable <br /> ;fan airflow as a function of load <br /> and comply with operational <br /> :requirements. <br /> 6.4:4.!;1. ;Insulation exposed to weather ❑Complies <br /> !protected from damage. s °' ❑Does Not <br /> !Insulation outside of the <br /> k , <br /> 1conditioned space and associated "'1 6 - ❑Not Observable <br /> s' <br /> with cooling systems is vapor eS _ ❑Not Applicable ; <br /> retardant. <br /> 6;4.4.1.2 ;HVAC ducts and plenums R- 1 R- ;❑Complies <br /> [ME8]2 i insulated. Where ducts or ! '❑Does Not <br /> I plenums are installed in or under ; I <br /> a slab,verification may need to ! ❑Not Observable <br /> ;[]Not Applicable <br /> 1 occur during Foundation ; ; <br /> +Inspection. <br /> , <br /> 6.4.4.1.3 I HVAC piping insulation thickness. in. i in, ❑Complies ; <br /> [ME9]? !Where piping is installed in or 1 ❑Does Not ° <br /> !under a slab,verification may <br /> need to occur during Foundation ;❑Not Observable <br /> Inspection. ; !❑Not Applicable <br /> 6.4:4.1:4- ,Thermally ineffective panel ? '° �` ❑Complies <br /> r ��i <br /> [ME41] ;surfaces of sensible heating " ❑Does Not <br /> panels have insulation>= R-3 5. <br /> i ❑Not Observable ; <br /> ❑Not Applicable I _ <br /> 6.4.4.2.1 I Ducts and plenums sealed based `` ❑Complies <br /> [ME10]2 :on static pressure and location. !`' ❑Does Not I <br /> ❑Not Observable <br /> r <br /> . ❑Not Applicable <br /> 1 High Impact(Tier 1) �.2` Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: Checkers Drive-IN Report date: 01/04/18 <br /> Data filename: P:\Valiant Equipment\FL Checkers\Checkers FL-Ashrae 90.1-2013-Miami.cck Page 11 of 19 <br /> 4 <br />