Laserfiche WebLink
Product Approval Method Method 1 Option D <br /> Date Submitted 06/18/2018 <br /> Date Validated 06/20/2018 <br /> Date Pending FBC Approval 06/26/2018 <br /> Date Approved 08/15/2018 <br /> Summary of Products <br /> Go to Page 10 Page 1/2® 1� <br /> FL# Model,Number or Name Description <br /> 15012.1 kfL; 2140,2141,2240,2241,2150, 06'-00"to 09'-00"wide by 20'high steel sectional door with <br /> 2151,2250,2251,2550,2551, or without polystyrene insulation. <br /> 4140,4141,4240,4241,4150, <br /> 4151,4250,4251,5240,5241, <br /> 5250, 5251,5940,5941,5950, <br /> 5951 <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s.pdf <br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z4-09-013L6 s.pdf <br /> Impact Resistant:No Verified By:John E.Scates,PE FL-51737 <br /> Design Pressure:N/A Created by Independent Third Party:Yes <br /> Other:Sectional doors provided for windload applications Evaluation Reports <br /> and have been tested in accordance with ASTM E330 and FL15012 R6 AE FL15012 Eval Rept pan r6 s.pdf <br /> ANSI/DASMA 108.Z4-09-013L6 Residential Pan 09'-00"wide Created by Independent Third Party:Yes <br /> @+23.2/-26.2 PSF,see drawing for additional widths and <br /> pressures. <br /> 15012.2 kgL; 2140,2141,2240,2241,2150, 06'-00"to 10'-00"wide by 20'high steel sectional door with <br /> 2151,2250,2251,2550,2551, or without polystyrene insulation. <br /> 4140,4141,4240,4241,4150, <br /> 4151,4250,4251,5240,5241, <br /> 5250,5251,5940,5941,5950, <br /> 5951 <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s.pdf <br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z5-09-013L6 s.pdf <br /> Impact Resistant:No Verified By:John E.Scates,P.E.FL-51737 <br /> Design Pressure:N/A Created by Independent Third Party:Yes <br /> Other:Sectional doors provided for windload applications Evaluation Reports <br /> and have been tested in accordance with ASTM E330 and FL15012 R6 AE FL15012 Eval Reot pan r6 s.odf <br /> ANSI/DASMA 108.Z5-09-013L6 Residential Pan 09'-00"wide Created by Independent Third Party:Yes <br /> @+27.3/-30.8 PSF,see drawing for additional widths and <br /> pressures. <br /> 15012.3 khI;2140,2141,2240,2241,2150, 09'-00"to 06'-00"wide by 20'high steel sectional door with <br /> 2151,2250,2251,2550,2551, or without polystyrene insulation. <br /> 4140,4141,4240,4241,4150, <br /> 4151,4250,4251,5240,5241, <br /> 5250,5251,5940,5941,5950, <br /> 5951 <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s.pdf <br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z6i-09-01507 s.pdf <br /> Impact Resistant:Yes Verified By:John E.Scates,P.E.FL-51737 <br /> Design Pressure:N/A Created by Independent Third Party:Yes <br /> Other:Sectional doors provided for potential"code-plus" Evaluation Reports <br /> applications.Large Missile impact(9 pound missile)and FL15012 R6 AE FL15012 Eval Rept pan r6 s.pdf <br /> cycling tests conducted in accordance with ANSI/DASMA 115. Created by Independent Third Party:Yes <br /> Static tests conducted in accordance with ASTM E330 and <br /> ANSI/DASMA 108.Z6i-09-01507 Residential Pan 09'-00"wide <br /> @+32.0/-36.2 PSF,see drawing for additional widths and <br /> pressures. <br /> 15012.4 kiL;2140,2141,2240,2241,2150, 06-00"to 09'-00"wide by 20'high steel sectional door with <br /> 2151,2250,2251,2550,2551, or without polystyrene insulation. <br /> 4140,4141,4240,4241,4150, <br /> 4151,4250,4251,5240,5241, <br /> 5250,5251,5940,5941,5950, <br /> 5951 <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ:No FL15012 R6 II Jamb Attachment Drawings s.pdf <br /> Approved for use outside HVHZ:Yes FL15012 R6 II Z7-09-013L6 s.pdf <br /> Impact Resistant:No Verified By:John E.Scates,P.E.FL-51737 <br /> Design Pressure:N/A Created by Independent Third Party:Yes <br /> Other:Sectional doors provided for windload applications Evaluation Reports <br /> and have been tested in accordance with ASTM E330 and <br />