Anchor:ITW Tapcon or Tapcon LDT or Simpson Strong-Tie Wedge-All. _ <br /> ITW Ramset/Redhead Tapcon, 1/4"diameter,2"long(minimum) <br /> ITW Ramset/Redhead Large Diameter Tapcon,3/8"diameter,2-3/4"long(minimum) r•t _ <br /> Simpson Wedge-All;3/8"diameter x 2"long(minimum). i <br /> Use a fastener for every track bracket unless the quantity of fasteners determined from this chart is more than the quantity <br /> of track brackets specified on the door drawing. 1 �' <br /> FASTENER SPACING Add track brackets as required to satisfy fastener spacing in these charts. Maximum spacing shown in chart. <br /> 2500 psi concrete Lesser spacing may be used to avoid interference with door hardware and or fastening system,but not less than 6". <br /> Simpson See chart for minimum edge distance required. <br /> Concrete walls shall be minimum 2500 psi concrete and shall be of sufficient strength to resist loads. <br /> Strong- Load per jamb=0.5 x door width x max positive pressure x door height. <br /> ITW Tapcon Tie Manufacturers installation instructions must be followed. <br /> 3/81' DOOR WIDTH (feet and inches)at a given DESIGN PRESSURE (PSF) <br /> Wedge- <br /> 1/4" 3/8" All 14psf 17psf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48psf 53psf 58psf 63psf 69psf 75psf 81psf 87psf 93psf <br /> 24 36 24 24'-3 20'-0 17'-0 14'-2 12'-1 10'-7 9'-5 8'-6 7'-8 7'-1 6'-4 5'-10 5'-4 4'-11 4'-6 4'-2 n/a n/a <br /> 24 36 22 26'-5 21'-9 18'-6 15'-5 13'-2 11'-7 10'-3 9'-3 8'-5 7'-8 6'-11 6'-4 5'-10 5'-4 4'-11 4'-6 4'-3 3'-11 <br /> 24 36 20 29'-1 24'-0 20'-4 17'-0 14'-6 12'-9 11'-4 10'-2 9'-3 8'-6 7'-8 7'-0 6'-5 5'-10 5'-5 5'-0 4'-8 4'-4 <br /> 24 36 18 32'-4 26'-8 22'-8 18'-1016'-2 14'-2 12'-7 11'-4 10'-3 9'-5 8'-6 7'-9 7'-2 6'-6 6'-0 5'-7 5'-2 4'-10 <br /> 24 36 16 36'-3 29'-10 25'-4 21'-2 18'-1 15'-10 14'-1 12'-8 11'-6 10'-7 9'-7 8'-9 8'-0 7'-4 6'-9 6'-3 5'-10 5'-5 <br /> 22 34 15 n/a 31'-8 26'-1122'-5 19'-3 16'-1014'-1113'-5 12'-3 11'-2 10'-2 9'-3 8'-6 7'-9 7'-2 6'-7 6'-2 5'-9. <br /> 21 32 14 n/a 33'-8 28'-7 23'-10 20'-5 17'-10 15'-11 14'-3 13'-0 11'-11 10'-9 9'-10 9'-1 8'-3 7'-7 7'-0 6'-7 6'-1 <br /> 19 30 13 n/a 35'-1130'-6 25'-5 21'-9 19'-1 16'-1115'-3 13'-1012'-8 11'-6 10'-6 9'-8 8'-10 8'-1 7'-6 7'-0 6'-6 <br /> 17 26 11 n/a n/a 35'-3 29'-4 25'-2 22'-0 19'-7 17'-7 16'-0 14'-8 13'-3 12'-1 11'-2 10'-2 9'-4 8'-8 8'-1 7'-6 <br /> 15 24 10 n/a n/a n/a 31'-9 27'-3 23'-10 21'-2 19'-1 17'-4 15'-11 14'-4 13'-2 12'-1 11'-0 10'-2 9'-5 8'-9 8'-2 <br /> 13 20 8 n/a n/a n/a n/a 32'-8 28'-7 25'-5 22'-1120'-1019'-1 17'-3 15'-9 14'-6 13'-3 12'-2 11'-3 10'-6 9'-10 <br /> 10 16 n/a n/a n/a n/a n/a n/a n/a 31'-9 28'-7 26'-0 23'-10 21'-7 19'-9 18'-2 16'-7 15'-3 14'-1 13'-2 12'-3 <br /> 9 14 n/a n/a n/a n/a n/a n/a n/a n/a 32'-8 29'-9 27'-3 24'-8 22'-6 20'-9 18'-1117'-5 16'-2 15'-0 14'-0 <br /> 8 12 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 31'-9 28'-9 26'-3 24'-2 22'-1 20'-3 18'-9 17'-6 16'-4 <br /> ITW Tapcon Simpson 14psf 17psf 20psf 24psf 28psf 32psf 36psf 40psf 44psf 48psf 53psf 58psf 63psf 69psf 75psf 81psf 87psf 193psf <br /> Strong' <br /> Tie DOOR WIDTH(feet and inches)at a given DESIGN PRESSURE (PSF) <br /> 1/4" 3/8" 3/8" FASTENER DIAMETER Supporting structural elements shall be designed by a registered <br /> professional engineer for wind loads in addition to other loads. <br /> 1.75" 2.5" 2.68" EMBEDMENT LENGTH \�tllll i I!1///� , This drawing does not address the wall design,but only door <br /> \\ s attachment.Wall construction is shown only for illustration <br /> Wall <br /> 3" 4" EDGE DISTANCE `��� 1�S' C4 V purposes. The building designer is responsible for ensuring that <br /> 0 the wall is sufficient to carry the door live and static loads. This <br /> 508# 764# 340# FASTENER LOAD CAPACITY _� �� drawing does not address the spring pad connections. Registered <br /> Nei.51737 Professional engineer may approved an alternative design. <br /> 000 SAL none <br /> John E.Scates,P.E. I�`I�nfJ <br /> 2560 King Arthur,Ste 124-54 i'0; STATE OF ❑OOD�• ` ❑ ❑ nATE <br /> Lewisville,Tx 75056 %70 '• <br /> 2-18-2015 <br /> Florida P.E.#51737 /j�*-►'•�ORQ #0 <br /> TXPE 56308,F-2203 /� a48 Concrete Wall <br /> // IONAL § Attachment Detail <br /> Digitally signed byJohn E.Scates P.E. � ��//lll 1111���\ � <br /> Date:2018.02.07 1`5:i0:42-06'00' C.H.I.Drawing: BJA-105 Rev.-06 <br /> Professional Engineer's seal provided only for verification of windload construction details. <br />