19-21626
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21626
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 12:43:35 PM
Creation date
4/15/2020 12:43:31 PM
Metadata
Fields
Template:
Building Department
Company Name
SUNSET ESTATES #2
Building Department - Doc Type
Permit
Permit #
19-21626
Building Department - Name
WOOSLEY,AARON & SMITH,DIRACE
Address
39250 8TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL NOTES Q <br /> ELECTRONIC VERSIONS OF STRUCTURAL DRAWINGS ARE THE SOLE, COPYRIGHTED PROPERTY OF KWA ENGINEERS LLC. ELECTRONIC <br /> VERSIONS SHALL NOT BE TRANSFERRED OR SHARED WITHOUT THE EXPRESS, WRITTEN PERMISSION OF KARINS ENGINEERING GROUP INC. SITE LOCATION <br /> STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL ;°: il;. :< :s:;L`,I: <br /> ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT <br /> SHOWN ON STRUCTURAL DRAWINGS. <br /> DIMENSIONS AND EXISTING CONDITIONS THROUGHOUT THE PROJECT SHALL BE FIELD VERIFIED. DISCREPANCIES SHALL BE <br /> BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD BEFORE PROCEEDING WITH THE AFFECTED PART OF THE WORK. <br /> THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE o <br /> CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE REPAIR PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING <br /> AND ITS COMPONENTS DURING REPAIR. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,TEMPORARY BRACING, «" .r <br /> GUYS OR TIEDOWNS. <br /> UNLESS CLEARLY SHOWN ON THE STRUCTURAL DRAWINGS, NO PENETRATIONS/CONDUITS SHALL BE MADE IN ANY STRUCTURAL <br /> MEMBER WITHOUT A PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE <br /> GENERAL CONTRACTOR TO IDENTIFY SUCH PENETRATIONS/CONDUITS BASED ON INFORMATION PROVIDED BY ALL SUBCONTRACTORS <br /> AND TO SUBMIT DETAILED AND DIMENSIONED FLOOR PLANS TO THE STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO <br /> IMPLEMENTATION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY LABOR AND MATERIALS ASSOCIATED WITH <br /> ADDITIONAL REINFORCEMENT OF STRUCTURAL MEMBERS RESULTING FROM INTRODUCTION OF SUCH PENETRATIONS/CONDUITS. <br /> DESIGN LOADS: 1 SITE LOCATION <br /> S—Q SCALE: N.T.S. <br /> THE STRUCTURAL SYSTEM FOR BUILDING DEPICTED HEREIN HAS BEEN DESIGNED ACCORDING TO THE FLORIDA BUILDING CODE <br /> 2017 (6TH. ED)" EXISTING BUILDING - CHAPTER 5 - REPAIRS. <br /> THE STRUCTURE HAS BEEN DESIGNED TO RESIST THE FOLLOWING SUPERIMPOSED LOADS: (!) . <br /> 1. ROOF LIVE LOAD ........ 20 psf = Q <br /> 2. ROOF DEAD LOAD'...... 10 psf - CL <br /> 3. CEILING DEAD LOAD ... 5 psf } W <br /> 4. WIND PRESSURE......... +16 psf/-28 psf (FACTORED) a; � <br /> i CL S <br /> N V) <br /> WOOD: c � <br /> STRUCTURAL WOOD COMPONENTS (TRUSS BRACING) SHALL BE CONSTRUCTED OF MINIMUM NO. 2 GRADE SOUTHERN PINE m <br /> ACCORDING TO AF&PA NDS. WOOD IN CONTACT WITH CONCRETE OR MASONRY,AND AT OTHER LOCATIONS AS SHOWN ON THE � <br /> DRAWINGS, SHALL BE PROTECTED OR PRESERVATIVE TREATED. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. <br /> PLYWOOD SHEATHING SHALL BE APA RATED 1/2 PERFORMANCE CATEGORY STRUCTURAL 1 EXPOSURE 1 AND COMPLY WITH <br /> APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE. <br /> MANUFACTURED PRODUCTS: <br /> ALL MANUFACTURED PRODUCTS INCLUDING BUT NOT LIMITED TO CONNECTORS, ADHESIVES, ENGINEERED LUMBER AND <br /> ACCESSORIES SHALL BE INSTALLED AND CURED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 8 <br /> CONNECTORS: S d <br /> CONNECTOR MODEL NUMBERS SHOWN ARE STRONG-TIE CONNECTORS AS MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, 2 SITE MAP <br /> U.N.O.,AND SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S DIRECTIONS TO RESIST THE SPECIFIED LOADS. S-0 SCALE: N.T.S. <br /> E <br /> UNLESS NOTED OTHERWISE FOR EACH CONDITION, ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL HAVE <br /> MINIMUM CORROSION RESISTANCE OF Z-MAX (OR EQUIVALENT) OR HOT DIP GALVANIZATION'WITH HOT.DIP GALVANIZED loco 11 <br /> FASTENERS. ALL EXPOSED CONNECTORS AND FASTENERS SHALL HAVE MINIMUM CORROSION RESISTANCE OF STAINLESS STEEL <br /> TYPE 316. <br /> t <br />