My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21652
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21652
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 1:29:31 PM
Creation date
4/15/2020 1:29:10 PM
Metadata
Fields
Template:
Building Department
Company Name
CRESTVIEW HILLS
Building Department - Doc Type
Permit
Permit #
19-21652
Building Department - Name
MASSEY,SCOTT
Address
7749 MERCHANTVILLE CIR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R y R W Building'Cionsultants, Ine-J <br /> Yy B Consulting and Engineering Services for the Building Industry <br /> C P.O.`Box230Valrico;FL33595 Photie813.b59.9197 <br /> F rida Board ofProfmional Engincersl Ccrtificate of Authorization No.9813: <br /> 0 / 'f/ Report I ! i <br /> Product <br /> Category Sub Category Manufacturer Product Name, <br /> Plastpro Inc. Smooth,I.Wood Grain[White Wood,Grain <br /> Exterior Swinging <br /> Exterior Door 5200-W.Century Blvd. Rustic.!Mahogany <br /> Doors Assemblies Los Angeles;CA Series N Fiberglass Door, <br /> yy Phone 440.969.9773 inswing Outswing:-"Non-impact" <br /> Scope. Product Evaluation report issil d by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Plastpro 1nc.;based on Rule.6tiapter No.61 G20-3,Method 1 D of the,State of Florida Ptodtict Approval;Department of <br /> Business:&:Professional Reg6lation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not.have nor will acquire financial interest in the company <br /> manufacturing or distributing a product or in any other entity involved in the.approval process of the product named <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with,the 6th Edition(2017)Florida Building Code.(FBC)structural requirements <br /> including the"High Velocity Hurricane Zo e'. <br /> 2: Product anchors=shall be as listed.and sp�ced as shown on details.-Anchor embedment to base material'shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in the."HVHZ"this product is lequired to be protected-wit an impact resistant covering that complies with Section 1626 of <br /> the FBC. iI <br /> 4- When used in areas outside of.the"HVH 'requiring wind borne debri' protectiion,this product is:teguired to,be protected with an <br /> impact-resistant covering that complies w th FBO Sections 1609.1.2&R301.2.12- <br /> 5. For 2x stud framing construction,_anchos g of these units shall be the same as that shown for 2x buck masonry.construction. r <br /> 6. Site conditions.that deviate from the de Lails of drawing FL-15220.8 require further engineering:analysis by a.licensed engineer or <br /> registered architect. <br /> 7. Outswing configurations meet:water inflirpltion requirements'for"HVHZ'. <br /> S. Inswing configurations do not meet the water infiltration requirements-Tor the"HVHZ'.,inswing units shall be installed only in non- <br /> habitable areas or at habitable locations l; otected.by an overhang or canopysuch that the angle:between the edge of canopy or <br /> overhang to sill is less than 45 degrees. ! <br /> 9. See drawing FL-15220.8 for size and des! n pressure limitations, <br /> Supporting Documents., <br /> 1. Test Report No. Test Standard Testing Laboratory Signed bV <br /> TEL 07-0223-2 TAS.202-94 II Testing Evaluation Lafi.,hic. Wendell Haney;RE: <br /> TEL 01390865 TAS202 94 !� Testing Evaluation Lab.;lnc. Wendell Haney,P.E. <br /> ETC 07-209-19303.0 ASTM D2843I11199,ASTM D635-98, ETC Laboratories Ben Meunier <br /> ASTM D192956 <br /> ETC08-209-20609.1 ASTM G155-y5a;D638-03' ETC-Laboratories GuijinderDhami <br /> ETC 06-255-17412.0 ASTM E84-01 ETC_Laboratories Joe Doldan,P.E. <br /> ETC 05-255A6776.0' ASTM G26-95;D2843-99,D635-98,. ETC.Laboratories Joe Doldan,P.E. <br /> D1929-96,DE 03 <br /> TEL 01391846 TAS202--94 II Testing Evaluation La-..;lnc. William Shelton,P.E. <br /> 2. Miami=Dade NOA Materials Testma <br /> 15-12Z3.02 HP Polypropyj ene{ODL) <br /> 3. Drawing No. Prepared b � �� �g; r.r_•, " Signed&Sealed by <br /> Na-FL-1.5220.8 RW Building Consultants,Inc.(CA#9813) 4 Lyndon F.Schmidt,P.E <br /> 4. Calculations Prepared b ,, =�Sv—e,u =� `o Signed&Sealed by <br /> Anchoring RW-Building Consultants,.Inc.(CA#9813) o o° Lyndon F.Schmidt,P.E- <br /> ASTM E1300 Glass Load. Lyndon F.:Sc midt,P.E. o N 0 `Z 4 O' _ <br /> 5. Quality Assurance m <br /> Certificate of Participation issued by National Accreditation and Management 9 <br /> Institute,certifying that Plastpro,.Inc.its man uf during products within_a quality <br /> assurance program-that complies with.ISOAE 17020 and Guide 53. <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> .9/26/2017 <br /> Sheet 1 of 1 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.