My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21653
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21653
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2020 9:30:17 AM
Creation date
4/15/2020 1:34:37 PM
Metadata
Fields
Template:
Building Department
Company Name
EMERALD POINTE RV RESORT
Building Department - Doc Type
Permit
Permit #
19-21653
Building Department - Name
KERNELL,DANNY
Address
3510 BERYL LANE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> ",,J"'TRINITYI ER® <br /> 4. PRODUCT DESCRIPTION: <br /> This Evaluation Report covers Norandex Vinyl Siding Systems in a variety of profiles and surface textures/ colors. <br /> This evaluation is limited to the specific product trade names referenced in this report subject to the Installation <br /> Requirements and Limitations/Conditions of Use herein. <br /> Brand Product Profiles Thickness . <br /> American Classic American Classic Insulated Siding System D4,D5DL,D6 0.044" <br /> Cambridge Beaded 6.5 Beaded 0.048" <br /> Finish Works Board&Batten 0.044" <br /> Generations Thermal Core Siding D4,D5DL,D6 0.044" <br /> Great Barrier D4,D5DL 0.044" <br /> Polar Wall Plus! D4,D5DL,D6 0.044" <br /> Norandex Sagebrush D4,D5DL 0.050" <br /> Shenendoah 6.5 Semi-Beaded 0.048" <br /> Shenendoah T3 0.040" <br /> Sterling D4,D5,D5DL 0.044" <br /> Summit Manor D4,D4.5,D4.5DL 0.040" <br /> Woodsman Select D4,D4DL,D5,D5DL 0.042" <br /> 5. LIMITATIONS: <br /> 5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the <br /> Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used <br /> for permitting or design guidance unless retained specifically for that purpose. <br /> 5.2 This evaluation report is not for use in FBC HVHZ jurisdictions. <br /> 5.3 Refer to FBC 1405.14 for prescriptively permitted installations based on the wind speed (Vasd),wall-height and <br /> Exposure for the project and its location. For installations and/or locations exceeding the prescriptively <br /> allowable installations,limitations relating to design wind pressure resistance are outlined in Appendix 1. <br /> 5.3.1 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind <br /> loads. Refer to FBC 1609 for determination of project-specific design wind pressures. The MDP for the <br /> selected installation shall meet or exceed the design wind pressure requirement for the project for each <br /> pressure zone. <br /> 5.3.2 Tables are based on wall cladding design wind pressure requirements in accordance with ASCE 7-10, <br /> multiplied by 0.6 (Pa,d)for allowable loads. <br /> 5.3.3 Use of Appendix 1 is limited to siding installations with sheathing on enclosed buildings (GCpi_±0.18), no load <br /> combinations (Kd = 1) and site conditions and location of the structure that do not meet all conditions <br /> specified in Section 26.8.1 of ASCE 7-10 (K,t= 1.0) at the stated maximum height. Analysis for buildings falling <br /> outside these constraints shall be on a project-by-project basis by a Florida Registered P.E. <br /> 5.3.4 Reference to "OK" indicates the system performance exceeds project requirements for that particular zone. <br /> Reference to"NO"indicates additional testing is required. <br /> 5.3.5 The dimension of Zones 4 and 5 (interior and end <br /> zones) shall be defined as 10% of the least <br /> horizontal plan-view dimension or 40% of the <br /> mean roof height, whichever is smaller, but not 15 j <br /> less than either 4% of the least horizontal plan- 5 4 9 ® a <br /> view dimension or 3 feet, as outlined in Figure o 0 <br /> 30.4-1 of ASCE 7-10. 5 s <br /> Exterior Research and Design,I.I.C. Evaluation Report C13820.04.09-1-R3 <br /> Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.12500-113 <br /> Norandex Vinyl Siding Systems;(517)780-3185 Revision 3:09/26/2017 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.