23.Tamper.Resistant Receptacles in accordance with 406.41 of the 2016 N.E.0 <br /> ' 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure, <br /> 25. R403.5.3Hot.water pipe insulation <br /> insul 1.ation for hot waster-pipe with a minimum thermal resistance (R-value)of R-3 shall.be applied to the <br /> following: <br /> Piping 3!:inch(1.9.1 mm)and larger,in.nominal diame_ter._ <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping frorn the-Water heater to:a distribution manifold: <br /> Piping located under.a floor slab.. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided.before C.O: <br /> 26.A copy ofthe-energy cacls shall be with permit at all times- <br /> 27.. Cone of- inal-'insulation report-shall be provided with permit before fn,4L <br /> 28. No fence,pool or screen enclosure Is issued with ihis.permit <br /> F.F.E.-Finished Floor Elevation <br /> F:B.C=Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way: <br /> A.D.A.-Americans with Disabilities Act N.E.C.-.National Electric Code(2016) <br />