My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21668
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21668
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 1:47:38 PM
Creation date
4/15/2020 1:47:30 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21668
Building Department - Name
LENNAR HOMES LLC
Address
39672 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_DA <br /> Building and Construction Services(BCS) <br /> JE I is C <br /> I i <br /> 4 V <br /> COUNTY FLORID Blower Door Test Report Form <br /> Property Address: Unit#;' <br /> I - Z <br /> Permit M. Test' o pan me: <br /> I <br /> Test Date: 17 <br /> Test rnA. , <br /> l� <br /> Teste Ce coritac <br /> i <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).As required by <br /> the Building Official,testing shall be conducted by an approved third party. A written report of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name) and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> i <br /> During testing:(check to verify condition rhet) <br /> Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> I <br /> Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> intended infiltration <br /> Interior doors if installed at the time of the test hall be open <br /> ,s pen <br /> - <br /> Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> Heating and cooling systems,if installed at the time of the test,shall be turned off <br /> Supply and return registers,if installed at the time of the test,shall be fully open <br /> f <br /> i <br /> j Vb Building volume(ft3) <br /> Q50 Airflow at 50 Pascal(CFM) _ <br /> I <br /> ACH5o Air changes per hour at 50 Pascal <br /> Qso x 60_Va = y� ACH50 (3.0 ACH minimum) <br /> Pass�1 Fail ❑ <br /> ❑Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> 1 hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida ergy Code requirements in accordance with Section R402.4.1.2. <br /> ,nature of Tester Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.