My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21669
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21669
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 1:48:31 PM
Creation date
4/15/2020 1:48:19 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21669
Building Department - Name
LENNAR HOMES LLC
Address
39684 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary W <br /> Job: 1551B,sfADSCarrierV <br /> wrightsoft@ Entire House Bye: DaVe2o,s <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> Design Information <br /> Weather: Tampa IntemationalAP,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70, °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 21972 Btuh Structure 17454 Btuh <br /> Ducts 1901 Btuh Ducts 2200 Btuh <br /> Central vent(0 ctm) 0 Btuh Central vent(0 ctm) 0 Btuh <br /> none (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 23873 Btuh Use manufacturers data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19654 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality SemHtight <br /> Fireplaces 0 Structure 1902 Btuh <br /> Ducts Central vent(0 cfm) 390 Btuh <br /> Heatingg Cool'ngg (none) <br /> Area(ft� 1555 1555 Equipment latent load 2292 Btuh <br /> Volume(fn 12700 12700 <br /> Air changesmour 0.26 0.14 Equipment Total Load(Sen+Lat) 21946 Btuh <br /> Equiv AVF(cfm) 55 30 Req.total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER,15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47-F Latent cooling 3600 Btuh <br /> Temperature rise 27 °F Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 Cfm <br /> Air flow factor. 0.034 dmBtuh Air flow factor 0.041 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point=32°F <br /> Backup:n/a n/a <br /> Input=0 kW, Output=0 Btuh,100 AFUE <br /> Calculations approved byACCA to meet all requirements of Manual J 8th Ed. <br /> -Fk wrightsoft^ Rght-Suite®Universal201919.0.07RSU05714 2019-Ju13007:age 1 <br /> ` Page 1 <br /> ACCA ...equipmenfl1551sfADSWV Tampa 2tonCarrierrup Calc=MJ8 Front Door faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.