Laserfiche WebLink
D <br /> Q <br /> V <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to.comply with R401.3 of the F:B.C: <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5: Driveways re ireR.O.W. use permit. All 4 sides of drivewaythru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be'met. <br /> 7. All,property markers shall be uncovered and marked at time:of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> 9: No electric,plumbing;mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section:R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall note i bnstalled iii a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 ofthe F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. MI 308A <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs.R702A.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.- They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 21 All 2016 N.E.C. Codes will be enforced. <br />