My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20765
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20765
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 6:57:35 AM
Creation date
5/11/2020 6:57:26 AM
Metadata
Fields
Template:
Building Department
Company Name
MURPHY OIL USA
Building Department - Doc Type
Permit
Permit #
19-20765
Building Department - Name
MURPHY OIL USA
Address
7623 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GOo Worldwide www.tyco-fire.com <br /> Contacts <br /> I <br /> Series ELO-231 B - 11.2 K-factor <br /> Upright and Pendent Sprinklers <br /> Standard Response, Standard Coverage <br /> for any given corrosive environment. <br /> General <br /> The effects of ambient temperature, <br /> concentration of chemicals, and gas/ <br /> Description chemical velocity, should be consid- 7 <br /> p y, ,c sl� rY, <br /> +_. TYCO Series ELO-231 B 11.2K Standard ered,as a minimum,along with the cor- _a <br /> Response,Standard Coverage Upright rosive nature of the chemical to which ' ' h <br /> and Pendent Sprinklers(Ref. Figure 1) the sprinklers will be exposed. ,. <br /> are automatic sprinklers of the frangible An upright intermediate level version <br /> - bulb type.They are standard response, of the Series ELO-231 B Sprinklers for <br /> spray sprinklers that produce a hemi- in-rack applications can be obtained by <br /> spherical water distribution pattern utilizing the Series ELO-231B Upright <br /> below the deflector. Sprinkler with the WSG-2 Guard & ; <br /> The 11.2 K-factor,ELO-231B Sprinklers Shield, and a pendent intermediate <br /> level version of the Series ELO-231B t, 1 <br /> were subjected to full-scale,high-piled <br /> storage fire tests to qualify their use Sprinklers can be obtained by utilizing =_ <br /> in lieu of 5.6 or K-factor standard the Series ELO-231 B Pendent Sprinkler <br /> spray sprinklers for the protection of with the WS-2 Shield. If there is a pos- <br /> high-piled storage. sibility of the pendent intermediate level <br /> version being exposed to mechanical <br /> Higher flow rates can be achieved at damage, a G-2 Guard can be added. ��•---...;..; <br /> much lower pressures with the 11.2 f <br /> ,i K-factor,ELO-231B Sprinklers,making IMUM <br /> :`="' <br /> their use highly advantageous in high <br /> The 11.2 K-factor, Series ELO-2318 i '✓ " I <br /> density applications, such as the pro- r•�•. <br /> j— Upright and Pendent Sprinklers <br /> tection of high-piled storage. <br /> � described herein must be installed f',i�y� �( <br /> Wax or lead coatings can be used and maintained in compliance with this t <br /> to extend the life of the copper alloy document,as well as with the applica- } ' <br /> components used in Series ELO-231B ble standards of the National Fire Pro- <br /> Sprinklers beyond that which would tection Association(NFPA), in addition <br /> otherwise be obtained when exposed to the standards of any other authori- .. <br /> to corrosive atmospheres. Although ties having jurisdiction. Failure to do so , <br /> wax, lead, and polyester coated sprin- may impair the performance of these <br /> klers have passed the standard corro- devices. <br /> sion tests of the applicable approval <br /> agencies, the testing is not repre- <br /> sentative of all possible corrosive taining their fire protection system Sprinkler <br /> _ atmospheres. Consequently, it is rec- and devices in proper operating con- <br /> ommended that the end-user be con- dition. Contact the installing contrac- Identification <br /> suited with respect to the suitability for or product manufacturer with any Numbers (SINS) <br /> of these corrosion resistant coatings questions. <br /> Installation of Series ELO-231B Pendent Refer to Table A for sprinkler identifica- <br /> IMPORTANT Sprinklers in recessed escutcheons will tion numbers. <br /> I Refer to Technical Data Sheet void all sprinkler warranties, as well as <br /> TFP2300 for warnings pertaining to possibly void the sprinkler's Approvals <br /> regulatory and health information. and/or Listings. <br /> Always refer to Technical Data <br /> Sheet TFP700 for the "INSTALLER <br /> WARNING"that provides cautions <br /> with respect to handling and instal- <br /> lation of sprinkler systems and com- <br /> ponents. Improper handling and <br /> installation can permanently damage <br /> a sprinkler system or its compo- <br /> nents and cause the sprinkler to fail <br /> to operate in a fire situation or cause <br /> it to operate prematurely. <br /> Page 1 of 6 AUGUST 2018 TFP342 <br />
The URL can be used to link to this page
Your browser does not support the video tag.