My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21741
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21741
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 7:00:24 AM
Creation date
5/11/2020 7:00:18 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21741
Building Department - Name
DR HORTON INC
Address
7088 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> z <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8"above the road elevation and'an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3.'of the F.B.C.- <br /> I Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides of.driveway ihru the sidewalk shall have <br /> -expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All,property markers shall be uncovered-and marked at time of first inspection. <br /> 8: All A.D.A.reguiremerits shall be met: <br /> 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the FAIC. (Fire-Separation), <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 off the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F:B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14: Return air in all bedrooms. IF. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum.board" shall not be used as a backer-in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.