Laserfiche WebLink
DocuSign Envelope ID:BEC83982-34AE-40B6-8A1D-0883A056Al9A <br /> ® 1800 I NAshton Blvd.s o,al <br /> Structural Group Lehi, UT 84043 <br /> J.Matthew Walsh,PE Kirk M.Nelson, SE Samuel Brown,PE-Civil <br /> Director of Engineering Structural Engineering Structural Engineering <br /> james.walsh@vivintsolar.com kirk.nelson@vivintsolarcom sam.brown@vivintsolar.com <br /> February 19,2020 <br /> Re: Structural Engineering Services <br /> Goldner Residence <br /> 5642 12th St, Zephyrhills, FL <br /> S-6315857; FL-01 <br /> To Whom It May Concern: <br /> We have reviewed the following information regarding solar panel installation on the roof of the above referenced <br /> home: <br /> 1. Site Visit by a representative from our office under my supervision identifying specific interior and <br /> exterior site information including the condition of the existing roof system and the size, spacing, and <br /> condition of existing structural framing members. Information gathered during the site visit includes <br /> photographs, sketches, and verification forms. <br /> 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to <br /> the existing roof. <br /> Based on the above information, we have evaluated the structural capacity of the existing roof system to support the <br /> additional loads imposed by the solar panels and have the following comments related to our review and evaluation: <br /> A. Description of Residence: <br /> The existing residence has typical wood framing construction with a maximum.of two layers of composite shingle <br /> roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard <br /> construction components. The designed areas of the home consist of the following framing methods: <br /> • Roof Sections: Dimensional lumber - 2x6 at 16" on center. Survey photos indicate that there was free <br /> access to verify the framing size and spacing. <br /> • Roof Sections: Dimensional lumber - 2x6 at 16" on center. Survey photos indicate that there was free <br /> access to verify the framing size and spacing. <br /> B. Loading Criteria <br /> 9.13 PSF= Dead Load(roofing/framing) <br /> 3.00 PSF= Dead Load (solar panels/mounting hardware) <br /> 12.13 PSF=Total Dead Load <br /> 20 PSF= Roof Live Load (based on local requirements) <br /> Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the <br /> Interior, Edge, and Corner Zones of the dwelling.) <br /> C.Solar Panel Anchorage <br /> 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. <br /> If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office <br /> should be notified before proceeding with the installation. <br /> • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website <br /> (www.a cofa ste n s o l a r.c o m). <br /> 2. The solar panels are 1%" thick. At no time will the panels be mounted higher than 10" above the existing <br /> surface of the roof. <br /> Page 1 of 210 _!rZ) 3 <br />