Laserfiche WebLink
f R W R W Building Consultants, Inc. <br /> BConsulting and Engineering Services for the Building Industry <br /> JL7 C P.O.Boa 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate of Authorization No.9813 <br /> B B � �BP D / i i <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> Wincore Window Company,LLC. 1700 19000 Series <br /> Windows Double Hung 260 Staunton Turnpike Vinyl Double Hung <br /> Parkersburg,WV 26104 Window <br /> "Non-Impact" <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# <br /> 1998)for Wincore Window Company, LLC. based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product <br /> Approval,Department of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitations. <br /> 1 <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity Hurricane Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> I <br /> 3. When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering <br /> that complies with FBC Sections 1609.1.2&R301.2.1.2. <br /> 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-15819.8 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-15819.8 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> TEL 02801070 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright <br /> TEL 02801071 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K.Wright <br /> 2. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-15819.8 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. ' <br /> 3. Calculations Prepared by Signed&Sealed by <br /> Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. <br /> ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation issued by National Accreditation and <br /> Management Institute,certifying that Wincore Window Company, LLC.is <br /> manufacturing products within a quality assurance program that complies <br /> with ISO/IEC 17020 and Guide 53. <br /> f� � !'•j''i t n /V <br /> 4 .4 <br /> {j`l`.N.tip� A <br /> ny 1>1 C ...`T <br /> .s. <br /> O <br /> �. it `"�'{...`'�•�- <br /> V <br /> 4�U�tit�i}SULVC� <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 7/19/2017 <br /> Sheet 1 of 1 <br /> I <br /> t <br /> I <br />