Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> C P.O.Boa 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate of Authorization No.9813 <br /> Dater.- / <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> Wincore Window Company,LLC. 7700/9906 Series <br /> Windows Fixed 260 Staunton Turnpike Vinyl Fixed Window <br /> Parkersburg,WV26104 "Non-Impact!' <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E..(System ID#1998) <br /> for Wincore Window Company,LLC.based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product <br /> Approval,Department of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity Hurricane Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or <br /> stucco. <br /> 3.When used in areas requiring wind bome debris protection this product is required to be protected with an impact resistant covering that <br /> complies with FBC Sections 1609.1.2&R301.2.12. <br /> 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-15816.6 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-15816.6 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> ATI B6715.02-501-47 AAMAIWDMA/101n.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> AT[C6371.02-501-47 AAMANVDMA/101/1.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> 2. Miami-Dade NOA Material <br /> 15-1201.11 Saflex° PVB Interlayer(Eastman Chemical Co.) <br /> 3. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-15816.E RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Calculations Prepared by Signed&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> ASTM E 1300 Glass Load Lyndon F.Schmidt,P.E. <br /> 5. Quality Assurance <br /> Certificate of Participation issued by National Accreditation and Management <br /> Institute,certifying that Wincore Window Company,LLC.is manufacturing <br /> products within a quality assurance program that complies with ISO/IEC <br /> 17020 and Guide 53. <br /> �G�tGGEEDFLi�G <br /> r�F,� <br /> 0 <br /> .° <br /> m <br /> NFG P� til;�l 1��',0�9 <br /> °E"��ti:EE6G2�'d <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 7/1 8120 1 7 <br /> Sheet 1 of 1 <br />