My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21717
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21717
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 7:53:40 AM
Creation date
5/11/2020 7:53:29 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21717
Building Department - Name
LENNAR HOMES LLC
Address
39622 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U�Irl"irI�K t�-) 4 d I --l--I-~ <br /> Jet Stream° Ultra Blowing Wool Insulation knorwoff <br /> Attic and Cavity Wall Card r�� e>t � r�3 bme,�6 Wt Wg <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'l."internal corrugation,a minimum length <br /> recommendations,Knout insulation baits and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 ibs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 Ibs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain an "'- The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's Instructions.Failure to install the <br /> insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label <br /> (R-value)of: not he less than: will result in lower installed R-values.Feld blending of this product with other loose fill insulations Is not recommended by the manufacturer. <br /> R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 tbs.,Minimum 31 lbs. <br /> R-38HD 10.25" <br /> R-38 12,00" R-Value* Bags per 1000 SF Maximum, Net Minimum <br /> R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF <br /> Insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 Ibs,/cu.ft. 16A bags 61.0 sq.ft. 0.525 tbs. <br /> R-21 HD 5.50" 2"x 5" 5.50" R-23 1.8 lbs./cu,ft. 25.8 bags 38.8 sq.ft. 0.825 tbs. <br /> R-19 6.25"" 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq,ft. 1.088 lbs. <br /> R-15HD 3.50" <br /> R-13 3.50" 2"x 10" 9.25" R-39 1.8 Ibs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 Ibs, <br /> R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,It is essential that this insulation be Installed property. <br /> FR-$ 2.50" <br /> "R�l 5R-cow ry.Conforms toASTM C 665 and FederalOpen Attic Application Bag Net Weight-Nominal 32 tbs.,Minimum 31 Ibs. <br /> tion HH-I-521F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this <br /> 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,080 SF of net area bag should not of installed Installed insulation bag should <br /> Ba slMSF Ba SlMSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> g 9 resistance(R-Value)of: than: more than: be less than than: than: <br /> Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .9521bs. 19.750" 19.750" <br /> R-Value Dimensions Framing Framing <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 tbs. 16.375" 16.375'. <br /> R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875' 14.875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 tbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 tbs. 10,375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 tbs. 9.125" 9.125" <br /> 2x8 22.4 22•7 R-22 9.8 102.2 SF .313 tbs. 7350" 7,750" <br /> 2x4 20.4 20.6 <br /> R-44 2x6 20.1 20.3 R-19 8A 119.3 SF .268 lbs. 6.750" 6.750' <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 tbs. 4.750" 4.750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 tbs. 4.000" 4.000" <br /> R-38 2x6 17.0 17.2 Bag Net Weight-Nominal 32 Its.,Orthum 31 lbs. <br /> 2x8 16.7 17.0 Coverage and installation data were determined using a VoluMae11 bbWmg machine in third gear%&Ah Vitale opening,2.0 psi air pressure and 150'et 3'Intemaitytantgated hose. <br /> This product Conforms to Hie perfamance reriukementsofASTM C 764,Type I,and cancelled Federal Speofcation HH-14030B,Type t,Class B.R-values are determined in accordance wish C 687 and C 518. <br /> 2x4 13.2 13.3 "R'means resistance to heal flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be Insider!property.0 you do It yoursell,get Instruc <br /> R-30 2x6 12.9 13.1 Hons and follow them carefully.Instructions do not come wth this package. <br /> "Based on Thud Party 2-year settling study,the predicted settlement over a 20-year pedad+muld he 1 percent or less.This amount of sefUmg Is theanaUy insignificant.Thera itup the instated and settled <br /> 2x8 12.6 - 12.9 lhcknessesareeNecHretyassame. <br /> 2x4 11.3 11.4 VaN-Matic9l is a registered trademark of Unisul. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R at aches <br /> 2x8 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at inches <br /> R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches <br /> 2x8 7:4 7.7 <br /> 2x4 5.3 5.4 Crawl Space Perimeter R at Inches <br /> R-13 2x6 5.0 5.2 Date Installed 5' <br /> 2x8 4.8 5.0 Blown insulation has been installed in conformance with the above recommen ations to provide an R-value of: <br /> 2x4 4.3 4.4 R- _using ZZ`> bags of this ins er��square feet of area <br /> R-11 2x6 4.1 1 4.3 1 at a minimum thi 0 es. <br /> 2x8 3.8 4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.