My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21720
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21720
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 7:54:50 AM
Creation date
5/11/2020 7:54:45 AM
Metadata
Fields
Template:
Building Department
Company Name
LINCOLN HEIGHTS
Building Department - Doc Type
Permit
Permit #
19-21720
Building Department - Name
SANTOS,IDALIA
Address
39352 LINCOLN AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rForcengineering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017,Sections 1504.3.2,1504.7. <br /> Product Description: Ultra-Rib Roof Panel, Min.29 Ga.Steel, 36" Wide,through fastened roof panel <br /> with fasteners through the panel rib over 1x4 wood purlins over one layer of <br /> asphalt shingles (optional) over min. 15/32" APA Plywood decking. Non- <br /> Structural Application. <br /> Panel Material/Standards: Material: Min.29 Ga.Steel conforming to Florida Building Code 2017 Section <br /> 1507.4.3. <br /> Yield Strength: Min.80.0 ksi <br /> Corrosion Resistance:Panel Material shall comply with Florida Building Code <br /> 2017,Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.016"min. <br /> Width: 36"maximum coverage <br /> Rib Height: %"major rib at 9"O.C. <br /> Panel Fastener: #9-15 x 2" HWH Woodgrip with sealing washing or approved equal through the <br /> panel rib <br /> %"minimum penetration through plywood <br /> Corrosion Resistance:Per Florida Building Code 2017,Section 1507.4.4. <br /> Substrate Description: Min.1x4 No.2 SYP wood purlins over maximum one layer of asphalt shingles/felt <br /> paper(optional)over min.15/32"thick APA rated plywood over supports at <br /> maximum 24"O.C. The 1x4 wood purlins shall be fastened to the plywood with <br /> (1)8d x 2%'Ring Shank Nail at 4"O.C. Design of 1x4 wood purlins,plywood and <br /> plywood supports are outside the scope of this evaluation. Substrate must be <br /> designed in accordance w/Florida Building Code 2017. <br /> Allowable Design Uplift Pressures: <br /> Table"A" <br /> Maximum Total Uplift Design Pressure: 52.5 psf 131.0 psf <br /> Fastener Pattern Through Panel Rib: 911-9"-9"-9" 9"-9"-9"-9" <br /> Fastener Spacing: 24"O.C. 6"O.C. <br /> *Design Pressure includes a Safety Factor=2.0. <br /> 40 <br /> IVo.444� / <br /> w � <br /> •s' STATE OF ;a <br /> pro <br /> FL#4595.22 R4 Aupzust 14, 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.