Laserfiche WebLink
Force Engineering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Underlayment: Per Florida Building Code 2017,Section 1507.1.1 and manufacturer's installation <br /> guidelines. <br /> Roof Panel Fire Classification: Fire classification is not part of this acceptance. <br /> Shear Diaphragm: Shear diaphragm values are outside the scope of this report. <br /> Design Procedure: Based on the dimensions of the structure,appropriate wind loads are <br /> determined using Chapter 16 of the Florida Building Code 2017 for roof cladding <br /> wind loads.These component wind loads for roof cladding are compared to the <br /> allowable pressure listed above.The design professional shall select the <br /> appropriate erection details to reference in his drawings for proper fastener <br /> attachment to his structure and analyze the panel fasteners for pullout and <br /> pullover.Support framing must be in compliance with Florida Building Code 2017 <br /> Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading. <br /> ACE <br /> CRNSF�,n�ri <br /> No.444� �= <br /> STATUE OF ; <br /> Zop <br /> Sttlr Aofllytiy Imo,;ss <br /> pxna I�� <br /> FL#4595.22 R4 Auaust 14, 2017 <br />