Laserfiche WebLink
I <br /> Silver Line <br /> SILVER LINE WINDOWS AND DOORS aAnElerseh <br /> a . <br /> f V1 SERIES170 <br /> 03' <br /> ONE SILVERDNE DRIVE <br /> NORTH BRUNSWICK,NI 08902 <br /> j SERIES PICTURE & FIXED SPECIALTY WINDOWS PH:80013Ca728 <br /> Z� E <br /> (29501MPACT/49501MPACT) �3a ¢ g5$^ <br /> �� <br /> Wok o �-� <br /> Cg� Z cc 9- <br /> oa9�-= <br /> I 3 Q smxP< <br /> L ZA`g' <br /> $ 2r- Pa o h o <br /> 8 GENERAL NOTES: 'a'+ z <br /> TABLE OF CONTENTS / <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND <br /> a Z ¢ Ca` <br /> MANUFACTURED TO COMPLY WITH THE CURRENT EDITION SHEET REVISION SHEET DESCRIPTIONto <br /> I'S r1 \ <br /> FLORIDA BUILDING CODE(FBC),EXCLUDING HVHZ AND HAS <br /> 9 BEEN EVALUATED ACCORDING TO THE FOLLOWING: 1 - GENERAL NOTES&GLAZING DETAILS <br /> • AAMA/WDMA/CSA 101/1.5.2/A440-11 REMARKS BY DATE <br /> 0 2 - ELEVATIONS&ANCHOR.LAYOUTS <br /> ASTM E1886-OS 6TH FBC EDITION FM 10/17 <br /> • ASTM E1996-12 3 - VERTICAL SECTIONS <br /> e <br /> 2. ADEQUACY OF THE EXISTING STRUCTURAL 4 - HORIZONTAL SECTIONS <br /> CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING 5 - INSTALLATION NOTES,ANCHOR DETAILS&SCHEDULE <br /> AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF <br /> WITHSTANDING AND TRANSFERRING APPLIED PRODUCT IN.Be IS THE PROP[gtt OE BUIIOING OPOPS.Ix[ <br /> D SIULLLNOT BE REPRODUCED IN WHOIEOR PART <br /> g LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE THDUTWRITTENCDNSENTOF BURDRIG DROPS.INC <br /> ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF ALTERATION <br /> 1,ADORI-1.1HIGHUGImNG,on DTNER <br /> MARKINGS TO THIS OOWME T ARE NOT PERMITTED AND <br /> D NSTALLATION. <br /> IWAEIDATE OUR CERTIFICATION. <br /> E DESIGN PRESSURE TABLE DIIII1,11y signed �Ifff�q�q,q FF Norem.P. <br /> 2 3.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND Beeson:I Ip11s�roying IIfiS�tyOm'enl <br /> ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE Date:? .1z> g13T <br /> i' STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE SIZE CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING <br /> RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD 1�y!/.• •.-'pO <br /> T, FOR THE PROJECT OF INSTALLATION. 56.0"X 73.0" SINGLE PICTURE +50/-50 PSF LARGE MISSILE 7 <br /> I 4.THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC <br /> AND MAY NOT REFLECT ACTUAL CONDITIONS FOR ASPECIFIC -O <br /> T T a SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE (Z/ <br /> FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED % O.o••', P•'�Z <br /> ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC / CC ••'••••••• <br /> DOCU' I AREA541N HVH2ENTS OR USE AREASWONE TITH IME EIS DOCUMENT PRODUCT AIPPROVAL TO 3/32/ANNEALED INSULATED GLASS - // SS/ONA�-��G <br /> a BE OBTAINED FROM MIAMI-DADE RER OR AHJ. 0.090 DUPONT PVB INTERLAYER HOM FLORIDAP WA� s <br /> e 3/32"ANNEALED BUILDING DROPST INC <br /> >: 31B E.DANIA BEALH BLVD./3Y <br /> 8 S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED INTERCEPT GLAZING AIRSPACE BANIA BEA61,R JJOW <br /> ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. iBPE CFRi DP AUTNORRATIOH H.anm <br /> SPACER 1/18"ANNEALED <br /> FL N: <br /> fi.WINDOW FRAME MATERIAL:PVC <br /> F L14918 <br /> e 7.GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS GLAZING NOTE: <br /> j CHARTS.SEE SHEET I FOR GLAZING DETAILS. GLASS THICKNESS AND TYPE SHALL DATE: 09•29.17 <br /> ^ 1/2"MIN.GLA99 <br /> COMPLY WITH ASTM E-1300 GLASS BITE EXTERIOR INTERIOR DWG.BY: CFI K.BY: <br /> 'D CHARTS REQUIREMENT <br /> GLAZING DETAIL CL HFN <br /> SCALE: NTS <br /> € DWG•g: SWD022 <br /> e i SHEET: <br /> a <br /> 2 .I <br /> OF 5 <br /> I <br /> I <br />