Laserfiche WebLink
D <br /> Q <br /> A <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. .T.E: shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: .Lots shall be graded to coriiply with R401.3:of the F.B.C. <br /> 3: Compaction.test required if 24'' or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete: <br /> 5: Driveways require.a R.O.W.use permit: All 4-sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: - All setbacksshall be met. <br /> 7. All property markers shall be uncovered_and.maeked_ at time of first inspection_ .- <br /> 8: All A.D.A. requirements shall:be met: _ <br /> 9. No.electric,plumbing,mechanical, or framing shall be covered without an inspect on.and -. <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the E.B-C. (Fire Separation).: <br /> -1.1. Appliances shall not be installed in a location where_subject_to mechanical.damage unless <br /> protected,by approved barriers. M303:4 of the RB.0 <br /> 12. water heaters shall comply with section P607.3 of-the F.B.C. <br /> 13: Foundation supports for A/C units.shall be raised at least 3" above finished grade. M 1308:1 <br /> . 14:Return air in all bedrooms: F.B.C. M1620:4 <br /> 1-5. Smoke detectors.are to be installed in accordance with R313:1 of the F.B.C_. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F.B:C: <br /> 17.-A11 means.of egress are to be in accordance with R311 of the F.B.C.. <br /> 18: "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. . <br /> 19.Combination-type AM breakers are required at all locations requiring:an AM.type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that'uses fossil-burning heating <br /> .. . <br /> or appliances or an attached garage.' They shall be installed in accordance with the RB.C: <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />