My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21806
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21806
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2020 8:36:13 AM
Creation date
5/11/2020 8:51:00 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21806
Building Department - Name
EADS,DUSTIN & BRITTNEY
Address
5905 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br /> P6ge 2 of 2 <br /> 3. The following mounting types shall be used. Please refer to the mounting details for the associated required <br /> penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per <br /> connection and therefore is adequate. <br /> • ECOFASTEN with ROCK-IT: (1) 5/16" lag screw. Pullout capacity based on National Design <br /> Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibsrnch penetration. <br /> 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC <br /> 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. <br /> 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind <br /> load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount <br /> types indicated above. The following values have been verified by in-house testing and the mounting hardware <br /> manufacturers'data, which are available upon request. Panel support connections should be staggered, where <br /> possible,to distribute load to adjacent members. <br /> Modules in Landscape Modules in Portrait <br /> Roof Zone Interior Ede Corner Interior Ede Corner <br /> Max Vertical Spacing in 40 40 40 66 66 66 <br /> Max Horizontal Spacing in 48 48 48 48 48 48 <br /> Max Uplift Load Ibs 335 267 247 566 451 417 <br /> D. Summary <br /> Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will <br /> adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation has <br /> been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida <br /> Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us <br /> at the time of this report. <br /> If there are any questions regarding the above, or if more information is required, please contact me. <br /> HERegards, ����\\�'P�� Nh�►���cl��� <br /> J. Matthew Walsh, PE = * ," N 84 <br /> FL License No. 84923 a * — <br /> p STATE OF ; <br /> 0 , <br /> 'FtORIDP,•G\�\\�� <br /> NAL <br /> 07/27/2019 <br /> ivint. <br /> _ , <br />
The URL can be used to link to this page
Your browser does not support the video tag.