Laserfiche WebLink
23.Zamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water'pipe insulation <br /> Insulation-for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> folloinring: <br /> Piping 44 inch (19.1 mm) and larger in nominal.diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to:a distribution manifold., <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A cony of the enemy cacls shall be with uermit at all tunes <br /> 27. Copy of final insulation:report shall-be provided with Permit before final. <br /> 2.8. No fence,pool or enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />