Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots_ shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Fiot water pipe insulation. <br /> Insulation for hot water pipe with a minimum_ thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3j;inch (19.1 mm)and larger in nominal diameter., <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to.a distribution manifold. <br /> Piping located under'a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation-systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26. A copy of-the eneM cacls shall be-with permit at all times <br /> 27. Copy of fMal-insulation report shall be provided with permit before rinah <br /> 28. No fence,pool or screen-enclosure is issued with.this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />