Laserfiche WebLink
o <br /> 4 <br /> F <br /> 'Sin le Family Dwelling <br /> Plan Review Comments <br /> 1. F.RE;.shall be a minimum of 8 above the road elevation and an engineered site.plan. <br /> 2 Lots shall be graded to.comply with R401:3 of the F.-B.C. <br /> 3: Compaction test required if 24"or more.of fill_dirt is brought in at any one.place. <br /> 4: Tie'in survey required before pouring concrete. <br /> 5; Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks:shall be met. <br /> 7. All property markers shall be uncovered acid marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: . <br /> 9; No electric,plumbing;mechanical, or framing shall.be covered without an inspection and . <br /> approval first: <br /> W.All Garages shall comply with section R302.6 of the F.B.C. (Fire'Separation): <br /> 11. Appliances shall.not be installed in a location where subject to mechanical damage unless <br /> protected by:approved barriers. M303.;4 of the F:B.0 <br /> 12.-Water heaters shall comply with section P607.3 of the RB:C: <br /> 13. Foundation supports for AX units:.shall.be raised at least 3" above finished grade. M1308.:1 <br /> 14. Returti air in-all bedrooms. F.B.C.. M1620.4 <br /> 15. Smoke detectors are to be.installed in accordance with.R313:1 of.the,F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F:B:C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C.. <br /> 18."Green.gypsum-board" shall not be used as a backer-in showers or tubs: R702.4.2 F.B.C. <br /> 10: Combination-type AM breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will bete in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.- They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,"mechanical, and electrical shall be separate.from unit to unit: This includes all <br /> underground plumbing and,electric. <br /> 22. All 201.6 N.E.C. Codes will be enforced. <br />