Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Development Code, lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water'pipe insulation. <br /> insulation for_hot.water pipe with a minimum thermal resistance I.(R-value) of R-3 shall be applied to the <br /> following: . <br /> Piping.314 inch (19.1 mm) and larger in nominal diameter. <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside the conditioned space:, <br /> Piping from the.water heater to a distribution manifold., <br /> Piping located under a floor slab.. <br /> Buried in piping. <br /> supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.-Blower door test shall be provided before C.O: <br /> 26 A copy of the enemy cacls shall be:with permit at all times <br /> 27. Copy of Thal insulation report shall be provided with permit before final <br /> 28:No fence,yool or screen enclosure :is issued with:thispermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act. N.E.C.-National Electric Code (2016) <br />