My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21871
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21871
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2020 8:43:20 AM
Creation date
5/11/2020 9:33:10 AM
Metadata
Fields
Template:
Building Department
Company Name
TIC OCC MOTWANI LLC
Building Department - Doc Type
Permit
Permit #
19-21871
Building Department - Name
TIC OCC MOTWANI LLC
Address
38935 COUNTY ROAD 54
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> WINN DIXIE#2487 PO Box 3613 <br /> 38901 COUNTY ROAD 54 E Apollo Beach, FL 33572 <br /> ZEPHYRHILLS, FL 33540 813-655-3373 <br /> 1-4 Letters FLEB#9394 <br /> Design per Florida Building Code, 6th Edition(2017),Section 16 Wind Load, <br /> ASCE 7-10, Load Case: D+0.6W Nathan P. Presnell, PE <br /> Design Specifications FLPE 77696 <br /> Risk Category II <br /> Kzt 1 <br /> Exposure Factor C <br /> Kd 0.85 <br /> Kz 0.98 <br /> V 140 (mph) <br /> GCp-GCpi 1.1 Zone 4, H<60 Feet �����_�.Q�N••E•N gkl•• <br /> ••..�s�t-'4�� <br /> Wind Pressure 46.0 (psf) ���`•'�.�C <br /> No 77696 ;< <br /> Sign Information Per Letter a <br /> Height 1.34 ft 'O <br /> I E OF <br /> Width 1.34 ftO •�: ` <br /> Distance grade to top Thickness1.00 30 (ft) i���''%* �•�R <br /> Wind Shear Force 36.96 (lb) <br /> Weight of Sign 18 (lb) DATE SIGNED: <br /> Total Shear Force= 41.10 (lb) 9/3/2019 <br /> Total Tension Force = 49.53 (Ib) <br /> Required Provided <br /> Fastener size Nominal 1/4 - 1/4 <br /> Minimum number of fasteners per letter 4 4 <br /> Shear Force per fastener(lb) 10.3 170 <br /> Tension Force per fastener(lb) 12.4 260 <br /> Combination Tension and 0.11 <1 O.K. <br /> Shear ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(1-1/2°EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 5/8'PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-112"EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/2°EMBEDMENT) <br /> CMU,SOLID CONCRETE,BRICK MASONRY SCREW(2"EMBEDMENT) <br /> 1HILTI HIT ROD W/HY-20 ADHESIVE(3112"EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> Winn Dixie 2487 Zephyrhills 1-4 Letters calc <br />
The URL can be used to link to this page
Your browser does not support the video tag.