Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots.shall be sodded before final at least_ 10 <br /> feet around the structure. <br /> 25. 14403.5.3Hot water.pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following:; <br /> Piping 3j, inch (1.9.1 mm)and larger in nominal diameter.. <br /> Piping serving more than_one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the_.Water heater to a distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and'return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower.door test si hAU be provided before CO <br /> 26.A copy of the enerzy caclsshall be with-permit at all times <br /> 27. Copy of that insulation'report shall be provided with permit before fnaL <br /> 28. No fence,pool or screen enclosure :is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6t'Edition <br /> R.O.W:-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />