My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21489
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21489
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 10:45:02 AM
Creation date
2/17/2021 8:55:40 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-21489
Building Department - Name
GAMBOCORTO,DANIEL & GAMBOCORTO,S
Address
38721 9TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MecaWind v2323 <br /> Software developer: Meca Enterprises Inc., www.meca.biz, Copyright n 2018 <br /> Calculations Prepared by: Calculations Prepared For: <br /> JUG CONSULTING ENGINEER Client: GAMBOCORTO D. RESIDENCE <br /> 17440 NE 4TH AVE. Project #: 19-085 <br /> N. MIAMI BEACH, FLORIDA, 33162 Location: PASCO COUNTY <br /> Date: Apr 26, 2019 <br /> Designer: JOSE D. GARCIA <br /> FileLocation : <br /> Basic Wind Parameters <br /> Wind Load Standard = ASCE 7-10 Exposure Category = B <br /> Wind Design Speed = 140.0 mph Risk Category = II <br /> Structure Type = Building Building Type = L Shaped <br /> General Wind Settings <br /> = ASCE 7-10 Wind Parameters = <br /> Incl_LF = Include ASD Load Factor of 0.6 in Pressures = True <br /> DynType = Dynamic Type of Structure = Rigid <br /> NF = Natural Frequency of Structure (Mode 1) = 1.000 Hz <br /> NF = Natural Frequency of Structure = 1.000 Hz <br /> Alt = Altitude (Ground Elevation) above Sea Level = 0.000 ft <br /> Bdist = Base Elevation of Structure = 0.000 ft <br /> GenElev = Specify the Elevations For Wind Pressures = Mean Roof Ht <br /> SDB = Simple Diaphragm Building = False <br /> MWFRS = Analysis Procedure being used for MWFRS = No Analysis <br /> C&C = Analysis Procedure being used for C&C = Ch 30 Pt 1 <br /> Reacs =Show the Base Reactions in the output = False <br /> MWFRSType = MWFRS Method Selected = No Analysis <br /> Topographic Factor per Fig 26.8-1 <br /> Topo = Topographic Feature = None <br /> Kzt = Topographic Factor = 1.000 <br /> Building Inputs <br /> RoofType: Building Roof Type = L Shaped Gabled = <br /> Ll Width of End 1 = 18.000 ft L2 Length Along Back = 32.000 ft <br /> L3 Width Along Side = 52.500 ft L4 Width End 2 = 21.500 ft <br /> EHt Eave Height _ = 10.000 ft RE Roof Entry Method = Slope <br /> Slope Roof Slope at End 1 = 3.0 :12 Endl Roof Type on End 1 = Hipped <br /> HS1 Hip Slope at End 1 = 3.0 :12 End2 End2 Method = Gabled <br /> OH Specify Roof to Wall intersection and Overhang= Overhang Par Is there a Parapet = False <br /> OHType Overhang Type = None <br /> I <br /> I <br /> Exposure Constants per Table 26.9-1: <br /> Alpha: Const from Table 26.9-1= 7.000 Zg: Const from Table 26.9-1= 1200.000 ft <br /> At: Const from Table 26.9-1= 0.143 Bt: Const from Table 26.9-1= 0.840 <br /> Am: Const from Table 26.9-1= 0.250 Bm: Const from Table 26.9-1= 0.450 <br /> C: Const from Table 26.9-1= 0.300 Eps: Const from Table 26.9-1= 0.333 <br /> Overhang Inputs: <br /> Std = Overhangs on all sides are the same = True <br /> OHType = Type of Roof Wall Intersections = Overhang <br /> OH = Overhang of Roof Beyond Wall = 1.330 ft <br /> Components And Cladding (C&C) Calculations per Ch 30 Part 1: (End 1) <br /> Zh = Shall not be less than 30 ft in Exp B [Table 30.3-1 Note 11 = 30.000 ft <br /> Kh = Since 15 ft [4.572 m] < Zh < Zg --> 2.01 * (Zh/zg)^(2/Alpha) = 0.701 <br /> Kzt = Topographic Factor is 1 since no Topographic feature specified = 1.000 <br /> Kd = Wind Directionality Factor per Table 26.6-1 = 0.85 <br /> GCPi = Ref Table 26.11-1 for Enclosed Building = +/-0.18 <br /> LF = Load Factor based upon ASD Design = 0.60 <br /> qh = (0.00256 * Kh * Kzt * Kd * V^2) * LF = 17.93 psf <br /> LHD = Least Horizontal Dimension: Min(B, L) = 32.000 ft <br /> al = Min(0.1 * LHD, 0.4 * h = 3.200 ft <br /> a = Max(al, 0.04 * LHD, 3 ft [0.9 m]) = 3.200 ft <br /> Wind Pressures for C&C Ch 30 Pt 1 (End 1) <br /> All wind pressures include a load factor of 0.6 <br /> Description Zone Width Span Area 1/3 Ref GCp GCp p p <br /> Rule Fig Max Min Max Min <br /> ft ft ft sq ft psf psf <br /> ----------- ---- ----- ----- ----- ---- ------- ----- ------ ----- ------ <br /> FIELD 1 3.330 5.420 18.05 No 30.4-2B 0.449 -0.874 11.27 -18.90 <br /> PERIMETER 2 3.330 5.420 18.05 No 30.4-2B 0.449 -1.572 11.27 -31.41 <br />
The URL can be used to link to this page
Your browser does not support the video tag.