Laserfiche WebLink
MecaWind v2323 <br /> Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright 0 2018 <br /> Calculations Prepared by: Calculations Prepared For: <br /> JDG CONSULTING ENGINEER Client: GAMBOCORTO D. RESIDENCE <br /> 17440 NE 4TH AVE. Project #: 19-085 <br /> N. MIAMI BEACH, FLORIDA, 33162 Location: PASCO COUNTY <br /> Date: Apr 26, 2019 <br /> Designer: JOSE D. GARCIA <br /> FileLocation : <br /> Basic Wind Parameters <br /> Wind Load Standard = ASCE 7-10 Exposure Category = B <br /> Wind Design Speed = 140.0 mph Risk Category = II <br /> Structure Type = Building Building Type = Enclosed <br /> General Wind Settings <br /> ASCE 7-10 Wind Parameters = <br /> Incl_LF = Include ASD Load Factor of 0.6 in Pressures = True <br /> DynType = Dynamic Type of Structure = Rigid <br /> NF = Natural Frequency of Structure (Mode 1) = 1.000 Hz <br /> NF = Natural Frequency of Structure = 1.000 Hz <br /> Alt = Altitude (Ground Elevation) above Sea Level = 0.000 ft <br /> Bdist = Base Elevation of Structure = 0.000 ft <br /> GenElev = Specify the Elevations For Wind Pressures = Mean Roof Ht <br /> SUB = Simple Diaphragm Building = False <br /> MWFRS = Analysis Procedure being used for MWFRS = No Analysis <br /> C&C = Analysis Procedure being used for C&C = Ch 30 Pt 1 <br /> Reacs = Show the Base Reactions in the output = False <br /> MWFRSType = MWFRS Method Selected = No Analysis <br /> Topographic Factor per Fig 26.8-1 <br /> Topo = Topographic Feature = None I <br /> Kzt = Topographic Factor = 1.000 <br /> Building Inputs <br /> RoofType: Building Roof Type = Flat Flat Roof = <br /> RfHt Roof Height = 10.000 ft W Building Width = 23.000 ft <br /> L Building Length = 30.500 ft OH Type of Overhang = Overhang <br /> Parapet Type of Parapet = None Par Is there a Parapet = False <br /> OH ALL Overhang = 1.250 ft <br /> Exposure Constants per Table 26.9-1: <br /> Alpha: Const from Table 26.9-1= 7.000 Zg: Const from Table 26.9-1= 1200.000 ft <br /> At: Const from Table 26.9-1= 0.143 Bt: Const from Table 26.9-1= 0.840 <br /> Am: Const from Table 26.9-1= 0.250 Bm: Const from Table 26.9-1= 0.450 <br /> C: Const from Table 26.9-1= 0.300 Eps: Const from Table 26.9-1= 0.333 <br /> Overhang Inputs: <br /> Std = Overhangs on all sides are the same = True <br /> OHType = Type of Roof Wall Intersections = Overhang <br /> OH = Overhang of Roof Beyond Wall = 1.250 ft <br /> Components And Cladding (C&C) Calculations per Ch 30 Part 1: <br /> Zh = Shall not be less than 30 ft in Exp B [Table 30.3-1 Note 13 = 30.000 ft <br /> Kh = Since 15 ft [4.572 m] < Zh < Zg --> 2.01 * (Zh/zg)^(2/Alpha) = 0.701 <br /> Kzt = Topographic Factor is 1 since no Topographic feature specified = 1.000 <br /> Kd = Wind Directionality Factor per Table 26.6-1 = 0.85 <br /> GCPi = Ref Table 26.11-1 for Enclosed Building = +/-0.18 <br /> LF = Load Factor based upon ASD Design = 0.60 <br /> qh = (0.00256 * Kh * Kzt * Kd * V^2) * LF = 17.93 psf <br /> LHD = Least Horizontal Dimension: Min(B, L) = 23.000 ft <br /> al = Min(0.1 * LHD, 0.4 * h = 2.300 ft <br /> a = Max(al, 0.04 * LHD, 3 ft [0.9 m]) = 3.000 ft <br /> Wind Pressures for C&C Ch 30 Pt 1 <br /> All wind pressures include a load factor of 0.6 <br /> Description Zone Width Span Area 1/3 Ref GCp GCp p p <br /> Rule Fig Max Min Max Min <br /> ft ft ft sq ft psf psf <br /> ----------- ---- ----- ----- ----- ---- ------- ----- ------ ---- ------ <br /> FIELD 1 3.330 5.420 18.05 No 30.4-2A 0.274 -0.974 9.60 -20.70 <br /> PERIMETER 2 3.330 5.420 18.05 No 30.4-2A 0.274 -1.620 9.60 -32.28 <br /> CORNER 3 3.330 5.420 18.05 No 30.4-2A 0.274 -2.364 9.60 -45.61 <br /> Area = Span Length x Effective Width <br />