D <br /> . . Single Family-Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with.R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks-shall be met. <br /> 7. All property markers shall be uncovered.and marked at time of first inspection.. <br /> 8: All A.D.A.-requirements shall be met: <br /> 9.. No electric,.plumbing;mechanical,or framing shall,be' covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302'.6 of the F.B.C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a'location where e-subjectj6 mechanical damage unless <br /> protected by approved barriers. M303A of the F.B.0 <br /> 12. water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for AX-units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air iri all bedrooms'. F.B.C. M1620.4 <br /> 15. Smoke:detectors are to be installed_ in accordance with R313:1 of the F.B.C. <br /> 16:All glazing requirements are to be in accordance:with R308.4 of the F:B.C: <br /> - <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. . <br /> 18. "Green.gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AM breakers are required at all locations requiring an AM type breaker. <br /> -20. Carbon monokide alarms will be required in-new construction that-uses fossil-burning heating <br /> or appliances or an attached garage. They shall be:installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced: <br />